SOFAR 7K~10.5KTLM-G3
User manual
Copyright © Shenzhen SOFAR SOLAR Co., Ltd
- 58 -
overvoltage
ID102
HwPVOCP
PV hardware overflows
ID103
HwACOCP
Ac output hardware
overflows
ID105
MeterCommFault
Meters communication
fault
Check whether the meters wiring is correct.
ID110
Overload1
Overload protection 1
Please check whether the inverter is
operating under overload.
ID113
OverTempDerati
ng
Internal temperature is
too high.
Make sure the inverter is installed where
there is no direct sunlight.
Please ensure that the inverter is installed in
a cool/well ventilated place.
Ensure the inverter is installed vertically
and the ambient temperature is below the
inverter temperature limit.
ID114
FreqDerating
AC frequency is too
high
Please make sure the grid frequency and
voltage is within the acceptable range.
ID129
unrecoverHwAc
OCP
Output hardware
overcurrent permanent
failure
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then switch ON
inverter. Check whether the problem is
solved.
If no, please contact technical support.
ID130
unrecoverBusOV
P
Permanent Bus
overvoltage failure
ID134
unrecoverAcOCP
Instant
Output transient
overcurrent permanent
failure
ID142
PermSpdFail(DC
)
PV surge protection
ID145
USBFault
USB fault
Check the USB port of the inverter
ID146
WifiFault
Wifi fault
Check the Wifi port of the inverter
ID147
BluetoothFault
Bluetooth fault
Check the bluetooth connection of the
inverter
ID152
SafetyVerFault
The software version is
inconsistent with the
safety version
ID154
SciCommLose(A
C)
SCI communication
error (AC)
ID156
SoftVerError
Inconsistent software
versions
Contact for technical support and software
upgrades.
7.2. Maintenance
Inverters generally do not need any daily or routine maintenance. Heat sink
should not be blocked by dust, dirt, debris or any other items. Before the