SOFAR 7K~10.5KTLM-G3
User manual
Copyright © Shenzhen SOFAR SOLAR Co., Ltd
- 49 -
6. Set Energy
Set the total power generation. You can modify the total power generation
through this option.
7. Set address
Set the address (when you need to monitor multiple inverters simultaneously) ,
Default 01.
8. Set Input mode
SOFAR 7K~10.5KTLM-G3 has three MPPT channels, which can run
independently or in parallel. Users choose the operation mode of MPPT
according to the system design. Parallel mode is applicable to the case where
one or two MPPT channels are in parallel., independent mode is applicable to
the case where three MPPT channels run independently, and the default mode is
independent mode.
9. Set Language
Set the inverter display language.
10. Set Anti Reflux
Enable or disable the anti-reflux function of the inverter, and set the reflux
power. This function need to be used with external CT, please refer to this
manual 4.4.3 CT for details.
“Enter”
1Enter setting
“OK”
1 Set Time
2 Event List
2 Clean Energy
“Up”
↑
3 System Info
“Up”
↑
3 Clean Events
“Down
↑
4 Display Time
“Down”
↑
......
5 Software Update
10 Set Reflux P
“OK”
Input password!
“OK”
****
Input 0001
0001
“OK”
Anti Reflux Control
Hard Anti Reflux Control
Anti Reflux Control
“OK”
Enable
“OK”
*.**KW
Input the allowable export power