![Sofar solar 10.5KTLM-G3 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/sofar-solar/10-5ktlm-g3/10-5ktlm-g3_user-manual_1311960030.webp)
SOFAR 7K~10.5KTLM-G3
User manual
Copyright © Shenzhen SOFAR SOLAR Co., Ltd
- 25 -
Figure 4-4 Connecting DC input power cables
1.Positive power cable 2. Negative power cable
Note:
L2 is 2 to 3 mm longer than L1.
Step 3
Insert the positive and negative power cables into corresponding cable
glands.
Step 4
Insert the stripped positive and negative power cables into the positive
and negative metal terminals respectively and crimp them using a clamping tool.
Ensure that the cables are crimped until they cannot be pulled out by force less
than 400 N, as shown in Figure 4-5.
Figure 4-5 Connecting DC input power cables
1.Positive power cable 2. Negative power cable
Step 5
Insert crimped power cables into corresponding housings until you hear a
"click" sound. The power cables snap into place.