General Specifications – S3008P

Aerial Platform

Working height   

4.56 m

Maximum platform height   

2.56 m

Wheelbase  

1 m

Ground clearance   

1.9 cm

Maximum wheel load   

220 kg

Maximum ground pressure   

92 kg/cm²

Floor loading   

1000 kg/m²

Weight, EVW   

Approximate  

350 kg

Stowed width  

76.2 cm

Stowed length   

1.23 m

Stowed height  

1.82 m

Platform

Dimensions  

51.3 cm x 109 cm

Guardrail height   

110.4 cm

Toeboard height   

15.3 cm

Rated work load   

240 kg

Maximum number of occupants   

1 indoors

Function Speed

Platform raise  

6 to 12 seconds

Platform lower   

8 to12 seconds

Lift Level Sensor Interlock

Side-to-side   

1.5 degrees

Front-to-rear  

2 degrees

Tires 

     

Nonmarking solid rubber 

Electrical System

Voltage  

12 V DC negative chassis ground

Source   

One - 12 V 105 amp hour battery

Fluid recommended   

distilled water

Charger   

15 amp

Hydraulic System

Maximum pressure  

19 305 kPa

Pressure Relief Valve Setting 

2,000 psi

Reservoir capacity  

3.78 l

System capacity  

3.78 l

Maximum operating temperature   

71°C (160°F)

Hydraulic fluid recommended   

Above -13°C (10°F)    ISO VG32 (Mobil DTE-13M)   

Below -13°C (10°F)    ISO VG15 (Mobil DTE-11M) 

Ambient Air Temperature Operating Range

Celsius   

-18°C to 43°C

Fahrenheit   

0°F to 110°F

Maximum Wind Speed

Indoor machines  

 0 m/s

Outdoor machines  

12.5 m/s

Vibration

      

  Whole body vibration < 0.5 m/sec²

Hand / Arm  vibration < 2.5 m/sec²

    

 

Sound Pressure Level 

 

At work station      

below 70 dB(A)

Specifications

 

Содержание S3006P

Страница 1: ...OPERATORS MANUAL Part Number 514690 000 EN S3008P sn 01 000800 01 00231 S3010P sn 01 000500 01 00559 S3006P sn 01 000500 01 00059 S3210P sn 01 000000 01 00001 January 2020 Original Instructions...

Страница 2: ......

Страница 3: ...9 Platform Raise Lower Buttons 9 Pre Operation Safety Inspection 10 System Function Inspection 10 Operation 12 Preparing for Operation 12 Lower Controls 12 Upper Controls 12 Platform 13 Raising and L...

Страница 4: ...42 EC This machinery also conforms to the following Directives EMC Directive 2014 30 EU The following standards have been used EN 12100 2010 EN 280 2013 A1 2015 EN 60204 1 2018 The machinery has been...

Страница 5: ...rations depending upon platform occupancy rating see operators manual decals Type 3 Harness attachment point Type 3 is rated for one lanyard attachment per loop as shown in the illustrations depending...

Страница 6: ...otice boards etc to the platform as this will increase wind loading IN CASE OF EMERGENCY push EMERGENCY STOP switch to deactivate all powered functions IF ALARM SOUNDS while platform is elevated STOP...

Страница 7: ...PUSH PRO 0120843 5...

Страница 8: ...artsinformation be sure to include the MODEL and SERIAL NUMBERS from the equipment nameplate Should the nameplate be missing the SERIAL NUMBER is also stamped on the front of the chassis Component Ide...

Страница 9: ...ol button is pressed to lower the platform the alarm emits a loud beeping sound to warn personnel in the work area to stand clear Danger Pinch points exist on the scissors structure Death or serious i...

Страница 10: ...d on the upper control panel in the platform Lower Controls The lower controls refer to Figure 2 are located on the right side of the chassis The following are located on the lower control panel Emerg...

Страница 11: ...e emergency stop is a two position red push button on the right side of the upper control panel Push the button inward to disconnect power from all control circuits at the upper controls Twist the but...

Страница 12: ...Check weekly that the fluid level in the batteries is correct See Battery Maintenance on page 15 4 Verify that the batteries are charged daily 5 Check daily that the AC extension cord has been disconn...

Страница 13: ...on button inward Test each machine function from the lower control station refer to Figure 2 6 Test the emergency lowering system for proper operation 7 Push the Lower Control Emergency Stop Button to...

Страница 14: ...rm Danger The aerial platform can tip over if it becomes unstable Death or serious injury will result from a tip over accident Do not exceed the capacity values indicated on the platform rating placar...

Страница 15: ...elease the controls wait for three seconds then operate the controls to lower again The allarm will sound the beacon will flash and there will be a 1 5 second delay before lowering begins Any re leasi...

Страница 16: ...dure to lift the aerial platform with a forklift 1 Properly stow the aerial platform 2 Engage the brakes on both of the rear wheels 3 Remove all personnel tools materials or other loose objects from t...

Страница 17: ...y from the battery Always wear safety glasses when working near the battery Battery fluid is highly corrosive Thoroughly rinse away any spilled fluid with clean water Always replace the battery with a...

Страница 18: ...ge drops off 9 Slide the component tray open to access the battery Remove the caps from the battery 10 Visually check the battery fluid level making sure the level is within 6 mm of the bottom of the...

Страница 19: ...erating controls Proper operation Emergency stop Shuts off lower controls proper operation Lowering alarm and interrupt Sounds when platform lowers proper operation Emergency Lowering Proper operation...

Страница 20: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Страница 21: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Страница 22: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Страница 23: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Страница 24: ...22 PUSH PRO 0120843 Manufacturer s Address Snorkel Europe Ltd Vigo Centre Birtley Road Washington Tyne Wear NE38 9DA UK...

Страница 25: ...l Distributore locale EUROPE MIDDLE EAST AFRICA ASIA PHONE 44 0 845 1550 057 FAX 44 0 845 1557 756 NORTH SOUTH AMERICA PHONE 1 785 989 3000 TOLL FREE 1 800 225 0317 FAX 1 785 989 3070 AUSTRALIA PHONE...

Отзывы: