background image

PUSH PRO -0120843

11

System Function Inspection

Refer to “Controls and Indicators” on page 6 for the 

locations of various controls and indicators.

!

Warning

STAND CLEAR of the work platform while 

performing the following checks.
Before operating the machine, survey the work 

area for surface hazards such as holes, drop-offs, 

bumps and debris.
Check in ALL directions, including above the 

work platform, for obstructions and electrical 

conductors.

1.  Move the machine, if necessary, to an 

unobstructed area to allow for full elevation.

2.  Pull the Lower Control Emergency Stop Switch to 

the ON position.

3.  Turn the Upper Control Emergency Stop Switch 

clockwise to the ON position.

4.   Visually inspect the scissors structure, lift cylinder, 

and hoses for cracked welds and structural 

damage, loose hardware, hydraulic leaks, loose 

wire connections, and erratic operation. Check 

for missing or loose parts.   

5.  Press and hold the ground operation button 

inward. Test each machine function from the 

lower control station (refer to Figure 2).

6.  Test the emergency lowering system for proper 

operation. 

7.   Push the Lower Control Emergency Stop Button 

to check for proper operation. All machine 

functions should be disabled. Pull the Lower 

Control Emergency Stop Button outward to 

resume.

8.  Enter the platform and close the gate. 
9.  Check that the route is clear of obstacles 

(persons, obstructions, debris), is level, and is 

capable of supporting the wheel loads.

10. Test each machine function from the upper control 

station by engaging the interlock and operating 

the function controls (refer to Figure 3).

11. Push the Upper Control Emergency Stop Button 

to check for proper operation. All upper control 

machine functions should be disabled. Turn the 

Upper Control Emergency Stop Button clockwise 

to resume.

12. Check to ensure that the Auto Brake system 

works correctly by raising the machine slightly 

from the lower controls. Check that the brake is 

engaged against the rear castor wheels. Check 

to make sure the machine will not move when 

elevated.

 

System Function Inspection

Содержание S3006P

Страница 1: ...OPERATORS MANUAL Part Number 514690 000 EN S3008P sn 01 000800 01 00231 S3010P sn 01 000500 01 00559 S3006P sn 01 000500 01 00059 S3210P sn 01 000000 01 00001 January 2020 Original Instructions...

Страница 2: ......

Страница 3: ...9 Platform Raise Lower Buttons 9 Pre Operation Safety Inspection 10 System Function Inspection 10 Operation 12 Preparing for Operation 12 Lower Controls 12 Upper Controls 12 Platform 13 Raising and L...

Страница 4: ...42 EC This machinery also conforms to the following Directives EMC Directive 2014 30 EU The following standards have been used EN 12100 2010 EN 280 2013 A1 2015 EN 60204 1 2018 The machinery has been...

Страница 5: ...rations depending upon platform occupancy rating see operators manual decals Type 3 Harness attachment point Type 3 is rated for one lanyard attachment per loop as shown in the illustrations depending...

Страница 6: ...otice boards etc to the platform as this will increase wind loading IN CASE OF EMERGENCY push EMERGENCY STOP switch to deactivate all powered functions IF ALARM SOUNDS while platform is elevated STOP...

Страница 7: ...PUSH PRO 0120843 5...

Страница 8: ...artsinformation be sure to include the MODEL and SERIAL NUMBERS from the equipment nameplate Should the nameplate be missing the SERIAL NUMBER is also stamped on the front of the chassis Component Ide...

Страница 9: ...ol button is pressed to lower the platform the alarm emits a loud beeping sound to warn personnel in the work area to stand clear Danger Pinch points exist on the scissors structure Death or serious i...

Страница 10: ...d on the upper control panel in the platform Lower Controls The lower controls refer to Figure 2 are located on the right side of the chassis The following are located on the lower control panel Emerg...

Страница 11: ...e emergency stop is a two position red push button on the right side of the upper control panel Push the button inward to disconnect power from all control circuits at the upper controls Twist the but...

Страница 12: ...Check weekly that the fluid level in the batteries is correct See Battery Maintenance on page 15 4 Verify that the batteries are charged daily 5 Check daily that the AC extension cord has been disconn...

Страница 13: ...on button inward Test each machine function from the lower control station refer to Figure 2 6 Test the emergency lowering system for proper operation 7 Push the Lower Control Emergency Stop Button to...

Страница 14: ...rm Danger The aerial platform can tip over if it becomes unstable Death or serious injury will result from a tip over accident Do not exceed the capacity values indicated on the platform rating placar...

Страница 15: ...elease the controls wait for three seconds then operate the controls to lower again The allarm will sound the beacon will flash and there will be a 1 5 second delay before lowering begins Any re leasi...

Страница 16: ...dure to lift the aerial platform with a forklift 1 Properly stow the aerial platform 2 Engage the brakes on both of the rear wheels 3 Remove all personnel tools materials or other loose objects from t...

Страница 17: ...y from the battery Always wear safety glasses when working near the battery Battery fluid is highly corrosive Thoroughly rinse away any spilled fluid with clean water Always replace the battery with a...

Страница 18: ...ge drops off 9 Slide the component tray open to access the battery Remove the caps from the battery 10 Visually check the battery fluid level making sure the level is within 6 mm of the bottom of the...

Страница 19: ...erating controls Proper operation Emergency stop Shuts off lower controls proper operation Lowering alarm and interrupt Sounds when platform lowers proper operation Emergency Lowering Proper operation...

Страница 20: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Страница 21: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Страница 22: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Страница 23: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Страница 24: ...22 PUSH PRO 0120843 Manufacturer s Address Snorkel Europe Ltd Vigo Centre Birtley Road Washington Tyne Wear NE38 9DA UK...

Страница 25: ...l Distributore locale EUROPE MIDDLE EAST AFRICA ASIA PHONE 44 0 845 1550 057 FAX 44 0 845 1557 756 NORTH SOUTH AMERICA PHONE 1 785 989 3000 TOLL FREE 1 800 225 0317 FAX 1 785 989 3070 AUSTRALIA PHONE...

Отзывы: