background image

16

PUSH PRO -0120843

Keep the charger dry.

1.  At the lower controls, turn the control selector 

switch to the off position. 

2.  Open the component tray to access the battery. 

Remove the caps from the battery.

3. 

Visually check the battery fluid level making sure 

the  level  is  within  6  mm  (¼″)  of  the  bottom  of 

the  filler  neck  inside  each  hole.  If  needed,  add 

distilled water.

4.  Tightly replace the caps on each battery and 

replace  and latch the battery tray covers.

5.  Plug the battery charger into a properly grounded 

outlet (

110 volt

 AC, 50/60 Hz) using a 3 conductor, 

1.5 mm (12 gauge) or larger extension cord. The 

extension cord must be as short as possible and 

in good electrical condition. 

6.  Visually inspect the battery charge indicator for 

proper charging rate. The LED is visible on the 

left side of the lower controls. Refer to Figure 7 

for the function of the LED. The battery should be 

fully charged when the LED is solid green. 

7.  Leave the battery charger plugged in until it shuts 

itself off. 

              

Figure 7 – Battery Charge Indicator

Note: If the charging cycle exceeds 16 hours without 

the battery being fully recharged, unplug the charger 

and have the battery checked.

8. 

After the battery charger turns itself off, it is not 

necessary to immediately unplug the extension 

cord from the battery charger. The charger will 

monitor the charge state of the battery and 

recharge them if the voltage drops off.

9.  Slide the component tray open to access the 

battery. Remove the caps from the battery.

10. 

Visually check the battery fluid level making sure 

the  level  is  within  6  mm  (¼″)  of  the  bottom  of 

the  filler  neck  inside  each  hole.  If  needed,  add 

distilled water.

11. Tightly replace the caps on the battery and close 

and latch the component tray.

Inspection and Maintenance Schedule

!

Caution

Frequency and extent of periodic examinations 

may depend on national regulations.

The Complete Inspection consists of periodic visual 

and operational checks, along with periodic minor 

adjustments that assure proper performance. Daily 

inspection will prevent abnormal wear and prolong the 

life of all systems. The inspection and maintenance 

schedule should be performed at the specified intervals 

and after prolonged periods of storage before returning 

the machine to service. Inspection and maintenance 

shall be performed by personnel who are trained and 

familiar with mechanical and electrical procedures.

!

Warning

Before performing preventative maintenance, 

familiarize yourself with the operation of the 

machine. Always block the scissors structure 

whenever it is necessary to perform maintenance 

while the platform is elevated.

The daily preventative maintenance checklist has 

been designed for machine service and maintenance. 

Please photocopy the Daily Preventative Maintenance 

Checklist and use the checklist when inspecting the 

machine.

Inspection and Maintenance Schedule

Standby : LED = Solid red

Charging : LED = Solid yellow

Fully Charged : LED = Solid green

Charging Error : Flashing Red

Содержание S3006P

Страница 1: ...OPERATORS MANUAL Part Number 514690 000 EN S3008P sn 01 000800 01 00231 S3010P sn 01 000500 01 00559 S3006P sn 01 000500 01 00059 S3210P sn 01 000000 01 00001 January 2020 Original Instructions...

Страница 2: ......

Страница 3: ...9 Platform Raise Lower Buttons 9 Pre Operation Safety Inspection 10 System Function Inspection 10 Operation 12 Preparing for Operation 12 Lower Controls 12 Upper Controls 12 Platform 13 Raising and L...

Страница 4: ...42 EC This machinery also conforms to the following Directives EMC Directive 2014 30 EU The following standards have been used EN 12100 2010 EN 280 2013 A1 2015 EN 60204 1 2018 The machinery has been...

Страница 5: ...rations depending upon platform occupancy rating see operators manual decals Type 3 Harness attachment point Type 3 is rated for one lanyard attachment per loop as shown in the illustrations depending...

Страница 6: ...otice boards etc to the platform as this will increase wind loading IN CASE OF EMERGENCY push EMERGENCY STOP switch to deactivate all powered functions IF ALARM SOUNDS while platform is elevated STOP...

Страница 7: ...PUSH PRO 0120843 5...

Страница 8: ...artsinformation be sure to include the MODEL and SERIAL NUMBERS from the equipment nameplate Should the nameplate be missing the SERIAL NUMBER is also stamped on the front of the chassis Component Ide...

Страница 9: ...ol button is pressed to lower the platform the alarm emits a loud beeping sound to warn personnel in the work area to stand clear Danger Pinch points exist on the scissors structure Death or serious i...

Страница 10: ...d on the upper control panel in the platform Lower Controls The lower controls refer to Figure 2 are located on the right side of the chassis The following are located on the lower control panel Emerg...

Страница 11: ...e emergency stop is a two position red push button on the right side of the upper control panel Push the button inward to disconnect power from all control circuits at the upper controls Twist the but...

Страница 12: ...Check weekly that the fluid level in the batteries is correct See Battery Maintenance on page 15 4 Verify that the batteries are charged daily 5 Check daily that the AC extension cord has been disconn...

Страница 13: ...on button inward Test each machine function from the lower control station refer to Figure 2 6 Test the emergency lowering system for proper operation 7 Push the Lower Control Emergency Stop Button to...

Страница 14: ...rm Danger The aerial platform can tip over if it becomes unstable Death or serious injury will result from a tip over accident Do not exceed the capacity values indicated on the platform rating placar...

Страница 15: ...elease the controls wait for three seconds then operate the controls to lower again The allarm will sound the beacon will flash and there will be a 1 5 second delay before lowering begins Any re leasi...

Страница 16: ...dure to lift the aerial platform with a forklift 1 Properly stow the aerial platform 2 Engage the brakes on both of the rear wheels 3 Remove all personnel tools materials or other loose objects from t...

Страница 17: ...y from the battery Always wear safety glasses when working near the battery Battery fluid is highly corrosive Thoroughly rinse away any spilled fluid with clean water Always replace the battery with a...

Страница 18: ...ge drops off 9 Slide the component tray open to access the battery Remove the caps from the battery 10 Visually check the battery fluid level making sure the level is within 6 mm of the bottom of the...

Страница 19: ...erating controls Proper operation Emergency stop Shuts off lower controls proper operation Lowering alarm and interrupt Sounds when platform lowers proper operation Emergency Lowering Proper operation...

Страница 20: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Страница 21: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Страница 22: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Страница 23: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Страница 24: ...22 PUSH PRO 0120843 Manufacturer s Address Snorkel Europe Ltd Vigo Centre Birtley Road Washington Tyne Wear NE38 9DA UK...

Страница 25: ...l Distributore locale EUROPE MIDDLE EAST AFRICA ASIA PHONE 44 0 845 1550 057 FAX 44 0 845 1557 756 NORTH SOUTH AMERICA PHONE 1 785 989 3000 TOLL FREE 1 800 225 0317 FAX 1 785 989 3070 AUSTRALIA PHONE...

Отзывы: