PUSH PRO -0120843
13
1. From the lower controls, pull the emergency stop
button outward (refer to Figure 2).
2. Insert the key into the control selector switch and
turn the switch to the upper controls position.
Note
The upper controls will not operate while the control
selector is in the lower position.
3. Enter the platform and secure the gate.
4. From the upper controls, turn the emergency
stop button clockwise to the on position (refer to
Figure 3).
5. The platform may be raised and lowered from the
upper controls.
Platform
Use care when entering and exiting the platform to
avoid slipping and/or falling. Securely close the safety
gate when the platform is occupied.
Raising and Lowering
Press and hold the interlock button on the left side of
the upper control box.
• To raise the platform, press and hold the platform
raise button until the desired height is reached.
• To lower the platform, press and hold the platform
lower button until the desired height is reached.
Lowering Interrupt (Arm Guard)
When the platform is lowered to about 1.5 m (5′)
lowering stops.This is the first decent limit the platform
will not lower for three seconds regardless of the
control position to allow personnel to clear the area
of the scissors before the platform completely lowers.
To continue lowering release the controls, wait for three
seconds then operate the controls to lower again. The
allarm will sound, the beacon will flash and there will
be a 1.5 second delay before lowering begins. Any re-
leasing of the controls below the first decent limit will
result in this 1.5 second delay being repeated the next
time the controls are operated.
Component Tray
Batteries and hydraulic components are enclosed in
the component tray on the left side of the chassis.
!
Danger
The aerial platform can tip over if it becomes
unstable. Death or serious injury can result from
a tip-over accident. Do not open the tray when the
platform is elevated.
To open the tray, lift up on the tray latch and pull the
tray open.
Emergency Lowering
Use the following procedure to operate the emergency
lowering system.
!
Warning
The potential for an accident increases when safety
devices do not function properly. Death or serious
injury can result from such accidents. Immediately
push the emergency stop button inward to disable
the control system before using the emergency
lowering system in the event of an emergency.
1. Immediately push the emergency stop button
inward to disable the control system in the event
of an emergency.
2. Make sure there is nothing in the way to obstruct
the platform when it lowers.
• Push downward on the lever to lower the
platform.
3. Make certain the lever/handle is fully released
and the emergency lowering valve is fully closed
before operating the aerial platform.
Operation
Содержание S3006P
Страница 2: ......
Страница 7: ...PUSH PRO 0120843 5...