201
Maintenance
M2 Scope/Meter
17.2.2 Replacing the Protective Handgrip
The soft protective handgrip that covers the outer edges of the Scanner is easily replaced should
it become worn or damaged. Contact your sales representative for replacement parts.
z
To replace the protective handgrip:
1. Disconnect the data cable, and any other cables, if attached to the Scanner.
2. From the bottom of the Scanner, gently lift up and out on one side of the handgrip to free it
from Scanner housing.
3. Repeat step 2 to loosen the other side of the handgrip.
4. Lift the handgrip off of the Scanner housing.
NOTE:
i
The handgrip tapers toward the front of the Scanner housing. Make sure the replacement
handgrip is correctly oriented before attempting to install it.
5. Fit the new handgrip over the top, data cable end, of the Scanner housing.
6. With your fingers, work the new handgrip onto the Scanner housing from top to bottom. Make
sure the tabs on the handgrip fit into the grooves on the housing.
17.3 M2 Scope/Meter
This section covers how to care for your M2 Scope/Meter.
17.3.1 M2 Scope/Meter Cleaning and Inspecting the M2 Scope/Meter
When using the M2 Scope/Meter, make sure to do the following:
•
Check the housing, wiring, and connectors for dirt and damage before and after each use.
•
At the end of each work day, wipe the housing, wiring, and connectors clean with a slightly
damp cloth.
IMPORTANT:
Do not use any abrasive cleansers or automotive chemicals to clean the Diagnostic Tool, cables,
or probes.
17.3.2 Replacing the Battery Pack
If the M2 Scope/Meter battery pack no longer hold a charge, contact your sales representative to
order a new one.
IMPORTANT:
The battery pack contains no user serviceable components. Tampering with the battery pack
terminals or housing will void the product warranty.
Replace the battery pack with the exact replacement rechargeable nickel-metal hydride (Ni-MH)
type battery only. Do not attempt to use standard (lead/zinc) batteries as they do not provide
sufficient power to operate the M2 Scope/Meter, and may leak and damage the tool.