ANNEX NXP Release 7.1 dated 19-02-2018
16
Index
Description
SMS settings
(AsynchMotor)
SMS Default
(PermMagnSync)
User settings
Unit
P 2.8.32
Max Overspeed
110,0
110,0
%
P 2.8.33
AdvancContFault
20
20
P 2.8.34
LowRefResponse
2 / Fault
2 / Fault
P 2.8.35
EncoderSupervis
1 / Disabled
0 / Enabled – For
Endat encoders
1 / Disabled – For
sin-cos encoders
P 2.8.36
PMSM Phase Check
1,0
1,0
%
G2.9 AUTO RESTART
P 2.9.1
Wait Time
3,00
3,00
s
P 2.9.2
Trial Time
60,00
60,00
s
P 2.9.3
Start Function
0 / Ramping
0 / Ramping
P 2.9.4
Undervolt. Tries
2
2
x
P 2.9.5
Overvolt. Tries
2
2
x
P 2.9.6
Overcurr. Tries
0
0
x
P 2.9.7
MotTempF Tries
2
2
x
P 2.9.8
Ext.Fault Tries
2
2
x
P 2.9.9
Stall Tries
3
3
x
P 2.9.10
SpeedError Tries
3
3
x
P 2.9.11
OverTorque Tries
3
3
x
G2.11 START TORQUE
P 2.11.1
StartUp Torque
0 / Not Used
0 / Not Used
P 2.11.2
StartupTorq Time
1000
1000
ms
P 2.11.3
Startup Torq Up
30,0
30,0
%
P 2.11.4
Startup Torq Dw
30,0
30,0
%
P 2.11.5
Torq Ref Select
1 / AI1
1 / A1
P 2.11.6
Full Load Level
100,00
100,00
%
P 2.11.7
No Load Level
0,00
0,00
%
P 2.11.8
Balance Level
50,00
50,00
%
P 2.11.9
Full Load Torque
80,0
80,0
%
P 2.11.10
No Load Torque
80,0
80,0
%
P 2.11.11
TorqueBrakeClose
30,0
30,0
%
G2.12 LICENSE KEY
P 2.12.1
License Key
0
0
For further information and advice contact:
Содержание TAKEDO-3VF
Страница 8: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 8 INTENTIONALLY BLANK PAGE ...
Страница 28: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 28 ASYNCHRONOUS MOTORS CLOSED LOOP ...
Страница 35: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 35 PERMANENT MAGNET SYNCHRONOUS MOTORS ...
Страница 50: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 50 ...
Страница 52: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 2 PAGE BLANK WITH PURPOSE ...
Страница 58: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 8 ...
Страница 59: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 9 ...