TAKEDO - 3VF NXP USER MANUAL Release P09.1 dated 01-12-2017
16
6.1 M1 = MONITOR
This menu displays values and data during inverter operation and it is split into 4 different sub-menus. The
caption V1
→
→
→
→
Vn appears under the name of the menu. This means ‘n’ quantities can be monitored.
Contents
Description
Content
s
Description
G1.1 Drive – Motor
V1.1.1
Output frequency
V1.1.8
DC-link Voltage
V1.1.2
FreqReference
V1.1.9
Unit temperature
V1.1.3
Motor Speed
V1.1.10 Advan Cont Memory
V1.1.4
Motor Torque
V1.1.11 Motor Power (absorbed)
V1.1.5
Motor power
V1.1.12 Overload Number
V1.1.6
Motor Current
V1.1.13 Current Limit Number
V1.1.7
Motor Voltage
G1.2 Input – Output
V1.2.1
DIN1
DIN2
DIN3
Up
Down
Emergency
V1.2.4
Programmable outputs:
DO1
R01
R02
Contactors Fault
Brake
V1.2.2
DIN4
DIN5
DIN6
High
Low
Inspection
V1.2.5
NXOPTB5 board programmable outputs:
RE1
RE2
RE3
Contactors Motor Block
Speed Detector
V1.2.3
with
NXOPTA2
board
DIN7
DIN8
Run Enable
Micro Brake
(term. 2)
(term. 4)
V1.2.6
Analog output / Analog Iout
V1.2.3
with
NXOPTA3
board
DIN7
DIN8
DIN9
Brake Micro 2 Brake Micro 1 Run Enable
(term. 2)
(term. 4)
(term. 28-29/A3)
G1.3 Ride Values
V1.3.1
Lift Speed m/s
V1.3.5
LowSpeedDistan (mm)
(Low speed distance)
V1.3.2
Encoder Freq (Hz)
(+ upward, - downward)
V1.3.6
FinalStopDistan (mm)
(Stop distance)
V1.3.3
TotalStopDistan (mm)
V1.3.7
Total Rope Rides
V1.3.4
Slowing Distan (mm)
(Slowing-down distance)
V1.3.8
Partial Rope Rides
G1.4 Braking A3
V1.4.1
Braking Space (mm)
V1.4.2
Mechanical Braking Space (mm)
V1.4.3
Steady Lift Space (mm)
Another very useful display is in menu M6 -
S6.11.1 = POWER MULTI-MONITOR
- pressing this key
displays motor current for
each phase
.
5.2 M2 = PARAMETERS
Full list of parameters with associated descriptions is in the paragraph “14 – PARAMETERS LIST”.
5.4 M4 = ACTIVE FAULTS AND WARNINGS
Listed below are the most common fault messages. Be careful not to reset the alarm or fault without first
having investigated the problems that caused the protection mechanism to cut in.
Always deselect the run command before resetting any fault.
Code
Description
Remedies / Indications
1
Overcurrent
: current 4 times the nominal value
detected at the inverter output.
Check the condition of cables and motor, also the
size of the inverter drive.
2
Overvoltage
: bus voltage is too high.
Increase the deceleration time, check the value
of the braking resistor.
5
Charge switch:
The charge switch is open when
the drive is in running.
Reset the fault and restart . If the fault happens
again, contact SMS.
7
Saturation trip:
several potential causes,
including a faulty component.
Cannot be reset from the keypad. Switch off power.
DO NOT RE-CONNECT POWER! Contact
manufacturer. If this fault appears simultaneously with
Fault 1, check motor cables
and motor
.
Содержание TAKEDO-3VF
Страница 8: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 8 INTENTIONALLY BLANK PAGE ...
Страница 28: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 28 ASYNCHRONOUS MOTORS CLOSED LOOP ...
Страница 35: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 35 PERMANENT MAGNET SYNCHRONOUS MOTORS ...
Страница 50: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 50 ...
Страница 52: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 2 PAGE BLANK WITH PURPOSE ...
Страница 58: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 8 ...
Страница 59: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 9 ...