TAKEDO - 3VF NXP USER MANUAL Release P09.1 dated 01-12-2017
45
14 – PARAMETER LIST (M2 Menu)
Contents
Description
SMS settings
(AsynchMotor)
SMS settings
(PermMagnSync)
User setting
Unit
G2.1 BASIC PARAMETERS
P 2.1.1
Current Limit
1.8 * I Inverter
1.8 * I Inverter
A
P 2.1.2
Motor Nom Voltg
380
400
V
P 2.1.3
Motor Nom Freq
50
8.00
Hz
P 2.1.4
Motor Nom Speed
1440
60
rpm
P 2.1.5
Motor Nom Currnt
I Inverter
I Inverter
A
P 2.1.6
Motor Cos Phi
0.82
0.9
G2.1.7 LIFT DATA
P 2.1.7.1
Lift Rated Speed
0.70
1,00
m/s
P 2.1.7.2
Pulley Diameter
520
320
mm
P 2.1.7.3
Gear Ratio
1.58
1.01
P 2.1.7.4
Ropes Ratio
1:1
1:1
P 2.1.7.5
Update Data
No
No
P 2.1.8
Identification
0
0
P 2.1.9
Fan control
3 / Speed control
3 / Speed control
P 2.1.10
ParEditPassword
0
0
P 2.1.11
Motor Type
0 / Async Induct
1 / PMSM
P 2.1.12
Encoder Type
0 / Incremental
0 / Incremental
P 2.1.13
EncoderDirection
Not Inverted
Not Inverted
P 2.1.14
Calculated Poles
4
16
P 2.1.15
ForcedPolesNum
0
0
P 2.1.16
Motor Rs
0,00
0,00
Ohm
P 2.1.17
Motor Xs
0,00
0,00
Ohm
P 2.1.18
Max Power
300,0
300,0
%
P 2.1.19
RopeRidesInit
0
0
G2.2 RUN CONFIGURATION
P 2.2.1
Max Frequency
50
8.00
Hz
P 2.2.2
NominalLinSpeed
0.70
1.00
m/s
P 2.2.3
Acceleration ramp
2.50
2.50
s
P 2.2.4
Deceleration ramp
2.00
2.00
s
P 2.2.5
Final Decelerat.
0.50
0.80
s
P 2.2.6
v0 000 zero
0,00
0,00
Hz
P 2.2.7
v1 100 high
50
8.00
Hz
P 2.2.8
v2 010 low
5.00
0.80
Hz
P 2.2.9
v3 110 high+low
25.00
4.00
Hz
P 2.2.10
v4 001 inspect.
25.00
4.00
Hz
P 2.2.11
v5 101 high+insp
25.00
4.00
Hz
P 2.2.12
v6 011 low+insp
25.00
4.00
Hz
P 2.2.13
v7 111 hi+lo+ins
25.00
4.00
Hz
P 2.2.14
Acc Inc Jerk
2.00
1.20
s
P 2.2.15
Acc Dec Jerk
0.6
0.6
s
P 2.2.16
Dec Inc Jerk
0.6
0.6
s
P 2.2.17
Dec Dec Jerk
1.20
1.20
s
P 2.2.18
Auto HalfF Dist
0
0
P 2.2.19
Half Floor Dist
1000
1000
mm
P 2.2.20
Half Floor Freq
25.00
4.00
Hz
G2.2.21 CLOSED LOOP
P 2.2.21.1
SmoothStartTime
0,00
0.00
s
P 2.2.21.2
SmoothStartFreq
0.30
0.10
Hz
P 2.2.21.3
Initial Acceler.
0.50
0.50
s
P 2.2.21.4
0 Hz TimeAtStart
0.700
1.00
s
P 2.2.21.5
0 Hz TimeAtStop
0.400
0.200
s
P 2.2.21.6
Stop Distance
0
0
mm
P 2.2.21.7
Final Stop Speed
0.50
0.10
Hz
P 2.2.21.8
Final Stop Time
0.050
0.20
s
P 2.2.21.9
Initial Speed
0
0
Hz
P 2.2.21.10 TotalDecDistance
0
0
mm
P 2.2.21.11 OptimStopSpeed
0
0
Hz
P 2.2.21.12 Test Mode
0 / No
0 / No
IMPORTANT: Parameters with a grey background should only be modified when advised by SMS!
Содержание TAKEDO-3VF
Страница 8: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 8 INTENTIONALLY BLANK PAGE ...
Страница 28: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 28 ASYNCHRONOUS MOTORS CLOSED LOOP ...
Страница 35: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 35 PERMANENT MAGNET SYNCHRONOUS MOTORS ...
Страница 50: ...TAKEDO 3VF NXP USER MANUAL Release P09 1 dated 01 12 2017 50 ...
Страница 52: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 2 PAGE BLANK WITH PURPOSE ...
Страница 58: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 8 ...
Страница 59: ...TAKEDO 3VF NXP Attachment for A3 Amendment Version 03 1 dated 01 12 17 9 ...