MENTOR 12 USER’S MANUAL
SECTION 1: PRODUCT INTRODUCTION – Page 19
2. Touch
the
Out 1
button of the
Binary Output
pad in the lower right corner of
the touch panel. The meter should beep until you touch the button again to
deactivate the output.
IMPORTANT:
Instead of using the meter, you may want to connect the binary
output to a binary input as described in the previous procedure. In
this case, you will get a
visual
feedback in the touch panel rather
than a sound signal from the meter.
Battery simulator setup and control
The procedure here is similar to checking the voltage power outputs described at the
beginning of this chapter. However, rather than
regulation,
you can
select
the battery
simulator’s DC output voltage from a set of predefined values in the range of 0-250 Vdc.
Set up your meter for DC measurement, connect its leads to the
Battery Simulator
pad
in the connections board, and do the following:
1.
Touch the ON button in the
Battery Simulator
pad at the bottom right corner of
the touch panel and check that the voltage displayed there is now being
measured by the meter.
2.
Switch to a different DC value by touching the
Battery Simulator
pad (not the
ON/OFF button) for a few seconds and selecting from the emerging window.
When you do this, the battery simulator’s output is automatically stopped, so
you should see zero in your meter’s display now.
3.
Repeat steps 1 and 2 if you want to check other available DC output values in
the battery simulator.