1st screen
After entering the values,
they can be registered by pressing “SET.”
Step Axis 1
Step No. 0
Posn 123.45 mm
Speed 100 mm/s
2nd screen
1st screen
2nd screen
The operation status
can be checked.
Monitor Axis 1
Step No.
1
Posn 12.34 mm
Speed 10 mm/s
Step
Axis 1
Step No.
0
Posn 50.00 mm
Speed 200 mm/s
Step
Axis 1
Step No.
1
Posn 80.00 mm
Speed 100 mm/s
“Easy Mode” for simple setting
Example of checking the operation status
Simple setting allows for immediate use!
Start testing
Move for the
constant rate
Setting of jog
and speed of the
constant rate
Step data
setting
Jogging
<When a PC is used>
Controller setting software
¡
Step data setting, test drive,
jogging, and move for the
constant rate can be set and
operated on one screen.
Step Data Input Type JXC5H/6H
Series
For immediate use, select “Easy Mode.”
<When a TB (teaching box) is used>
Teaching box screen
¡
The simple screen without scrolling
promotes ease of setting and operation.
¡
Choose an icon from the first screen
to select a function.
¡
Set the step data and
check the monitor on
the second screen.
¡
Data can be set by inputting
only the position and speed.
(Other conditions are preset.)
Example of setting the step data
p.
29
Step motor
(Servo/24 VDC)
JXC5H/6H
3
Controllers
JXC
m
Series