q
w
Confirm that the combination of the controller and actuator is
correct.
The controller is sold as single unit after the
compatible actuator is set.
<Check the following before use.>
q
Check the actuator label for the
model number. This number should
match that of the controller.
w
Check that the Parallel I/O
configuration matches (NPN or PNP).
How to Order
Specifications
*
Refer to the “Operation Manual” for using the products. Please download it via our website:
https://www.smcworld.com
Model
JXC5H
JXC6H
Compatible motor
Step motor (Servo/24 VDC)
Power supply
Power supply voltage: 24 VDC
±
10%
Current consumption (Controller)
100 mA or less
Compatible encoder
Battery-less absolute
Parallel input
11 inputs (Photo-coupler isolation)
Parallel output
13 outputs (Photo-coupler isolation)
Serial communication
RS485 (Only for the LEC-T1 and JXC-W2)
Memory
EEPROM
LED indicator
PWR, ALM
Cable length [m]
Actuator cable: 20 or less
Cooling system
Natural air cooling
Operating temperature range [
°
C]
0 to 40
Operating humidity range [%RH]
90 or less (No condensation)
Insulation resistance [M
Ω
]
Between all external terminals and the case: 50 (500 VDC)
Weight [g]
180 (Screw mounting), 200 (DIN rail mounting)
High Performance Controller
(Step Data Input Type)
JXC5H/6H
Series
JXC 5 H 7 3
w e r
t
q
w
Specification
H
High performance type
e
Mounting
7
Screw mounting
8
DIN rail
q
Controller type
5
Parallel I/O (NPN) type
6
Parallel I/O (PNP) type
r
I/O cable length
Nil
None
1
1.5 m
3
3 m
5
5 m
t
Actuator part number
Without cable specifications and actuator options
Example: Enter “LEG32MDGB-30” for the
LEG32MDGB-30C-R1C
m
1
mm
.
BC
Blank controller
*
1
*
1 Requires dedicated software (JXC-BCW)
For details, refer to page 43 and onward.
[CE/UKCA-compliant products]
EMC compliance was tested by combining the
electric actuator LEG series and the controller
JXC series.
The EMC depends on the configuration of the
customer’s control panel and the relationship with
other electrical equipment and wiring. Therefore,
compliance with the EMC directive cannot be
certified for SMC components incorporated into
the customer’s equipment under actual operating
conditions. As a result, it is necessary for the
customer to verify compliance with the EMC
directive for the machinery and equipment as a
whole.
Caution
29