-46-
9. Trouble shooting
9.1 Alarm and Warning
POINT
●
Turn the servo-ON (SON) OFF and shut off the main circuit power supply as
soon as the alarm occurs.
An alarm or warning is displayed when an abnormality occurs during operation. When an alarm or warning
occurs, take appropriate measures according to "LECSN-T Operation Manual, Chapter 8”. When an
alarm occurs, the ALM is turned off.
The alarm can be cleared by any of the methods marked with a circle (
○
) in the Alarm Clear column after
removing the cause of the alarm. The warning is automatically cleared when the cause is removed.
9.3 Alarm Display
The contents of the alarm / warning that is currently occurring in the driver are displayed in the alarm
display function of the setup software.
In addition, history is listed for alarms that occurred in the past.
①
Click “Diagnosis” - “Alarm Display” of the setup software to display “Alarm Display” window.
②
Alarms / warnings currently occurring in the driver display the contents.
If no alarm / warning has occurred, it will not be displayed.
③
Lists the history (Maximum 6 cases) of alarms that occurred in the past.
(Warnings are not displayed.)
①
②
③