![SMC Networks LECSN-T Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/smc-networks/lecsn-t-series/lecsn-t-series_operation-manual_1299644034.webp)
-33-
6.2
Display
All Monitor List
The method how to obtain the electric actuator condition is described with the display all function of the
setup software.
①
Click “Monitor” - “Display All” of the setup software to display “Display All” window.
②
The condition of each item is displayed.
For off line of the setup software, [----] will be displayed.
Typical display items are shown below.
No.
Name
Function
Display range
Unit
1
Current position
The actual current position where the machine home
position is assumed as zero is displayed.
-9999999 to
9999999
× 10STM
mm
2
Command position The position data in the point table or the present
command position is displayed.
-9999999 to
9999999
× 10STM
mm
3
Command
remaining distance
The residual distance up to position command of the
currently selected point table is displayed.
-9999999 to
9999999
× 10STM
mm
4
Cumulative
feedback pulses
Feedback pulses from the motor encoder are counted
and displayed.
When exceeding 999999999, it returns to zero.
Press the [Clear] button to reset the display value to
0 (zero).
Reverse rotation is indicated by a minus (-) sign.
-999999999 to
999999999
pulse
5
Motor speed
The motor speed is displayed.
The value rounded off is displayed in 0.1r/min.
-7200 to
7200
r/min
①
②