-32-
6.1.3 Operation Instruction
When the PLC on the master side sends the operation command, the actuator will operate.
When the trigger conditions in 6.1.1 (2) are satisfied, the operation waveforms can be captured.
When the time set in 6.1.1 (1) has passed after the acquisition start, the acquisition of the waveforms will
complete, and waveforms are displayed on the screen.
When the “Scale Optimization” button is clicked, the vertical axis range is adjusted automatically.
6.1.4 Saving of waveform
After the waveform is displayed, it is possible to save the data in 3 ways.
①
Click the “Save As” button.
Select the folder in which the step data is to be saved and save the data.
Waveform data file
(extension: gpf2) will be prepared.
If the waveform condition needs to be checked, it can be
displayed on the graph window.
②
Click the “Save Image” button.
Select the folder in which the step data is to be saved and save the data. An Image file (extension:
jpg) will be prepared.
③
Click the “Screen Copy” button.
Save the displayed waveform screen (print screen).
①
①
②
③