-24-
5.3.3 Parameter Configuration Method (Ex.
“Control mode” Selection)
Please set the parameters for each actuator.
Please change the parameter values according to usage.
Refer to "LECSC
Operation Manual”,chapter 6 for details of each parameter.
Refer to
“LECSC Operation Manual (Simplified Edition)”,section 5.4.3 for recommended parameter values for SMC
supplied actuators.
・
Setting example of the Control mode (PA01) (in the case of setting to
"Absolute value command
system").
①
Set the parameters of the PA01 to "0000" in the "Basic" tab.
・
Setting example of the Control mode (PA01) (in the case of setting to
“Incremental value command
system
”).
①
Set the parameters of the PA01 to "0001" in the "Basic" tab.
②
Click on the "Single Axis Write" button.
③
Turn the power OFFand ON again. The Parameter is then enabled.
When changing of each parameter, note the following points.
Note1) Some of the various parameters, there is "Enable once on again turning the power OFF after setting".
(If you do not the power to OFF, it does not reflect the data in the driver.)
Note2)
“Selected Items Write”: It writes the parameter values of the corresponding frame to the driver.
“Single Axis Write”: It writes all of the parameters to the driver.
Note3)
Do not change “For manufacturer setting” parameters.
If you change by these by mistake, it may cause
the amplifier to not work properly.
①
②