-13-
3.2 I/O signal connection
3.2.1 Connection example (Sink I/O interfaces)
An example of a connection for the I/O signal connection is shown below. Connect wires as necessary.
SD
LBR
LAR
LA
LB
LZ
LZR
LG
15
12
25
RA1
RA2
RA3
14
RD
ALM
16
ZP
CN6
11
24
13
26
1
2
3
Plate
4
5
17
EMG
DOG
LSP
LSN
DICOM
DOCOM
23
+
MR-J3USBCBL3M
(Option)
CN5
(Note 7)
MR Configurator
Personal
computer
CN1
CC-Link
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Control common
Encoder Z-phase pulse
(differential line driver)
24VDC
power
supply
(Note 4)
(Note 8)
Proximity dog
Forward rotation stroke end
Reverse rotation stroke end
(Note 3, 5)
(Note 9)
(Note 5)
Forced stop
(Note 9)
Ready
Trouble (Note 6)
Home position
return completion
(Note 2)
10m or less
Servo amplifier
CN6
10m or less
(Note 1)
Refer to
“
LECSC
Operation Manual”,section 4.2 for wiring details.
Refer to
“
LECSC
Operation Manual”,section 4.5 for input/output signal details.
Driver
LEC-MR-J3US
B
(Note 7)
Set up software
(
MR Configurator
)