- 16 - 

 

 

4.3 Parameter setting   

Confirm that "2: Absolute" is selected for the setting of "Sensor type" in order to enable the controller 

absolute function. (Default setting is “2: Absolute”.) 

 

Basic parameter details (Items exclusive to absolute controller)

 

Description 

Input 

range 

Content 

Controller 

Software 

Teaching 

box 

Sensor type  Sensor type 

1, 2 

1: Incremental (Encoder signal is not backed up when the power supply is cut) 

2: Absolute (Encoder signal is backed up when the power supply is cut) 

* When the parameters are changed, they are valid after restarting the power supply. 

 

 

  Caution 

When "1: Incremental" is selected, absolute function becomes invalid. 

 

 

 

Содержание LECP7-XB54 Series

Страница 1: ...PRODUCT NAME Absolute Controller Without Battery Step Motor Servo 24V DC Model Series LECP7 XB54 Series Doc No TQ0870054 OM004...

Страница 2: ...14 4 Preparation for Operation 15 4 1 Charging of the battery 15 4 2 Setting the power supply period by switch setting 15 4 3 Parameter setting 16 4 4 Parallel I O signal details 17 5 Operation 22 5...

Страница 3: ...oup D when the power is supplied again 27 5 3 3 Power supply is cut due to alarm group E 29 6 Alarm detection 30 6 1 Alarm contents and countermeasures 30 7 Absolute Controller Specific Product Precau...

Страница 4: ...e product is the responsibility of the person who designs the equipment or decides its specifications Since the product specified here is used under various operating conditions its compatibility with...

Страница 5: ...recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circuits in press applications safety equipment or other applications unsuitable for the standard s...

Страница 6: ...the product is delivered 3 Also the product may have specified durability running distance or replacement parts Please consult your nearest sales branch 2 For any failure or damage reported within th...

Страница 7: ...ed as dangerous Class 9 for sea transport only This product is a non dangerous article for sea transport as of August 2012 When transporting a nickel metal hydride battery or equipment containing nick...

Страница 8: ...position is necessary for the following conditions 1 Supplying power to the controller for the first time 2 Alarm group D is generated when the power to the controller is supplied again e g Battery di...

Страница 9: ...absolute ENC alarm Code 154 Encoder signal counting error 2 Continuous charging of the battery is necessary When power is supplied to the controller for the fist time please energize continuously to c...

Страница 10: ...l None 1 1 5m 3 3m 5 5m Nil None D DIN rail Actuator Actuator cable length Actuator type Refer to How to order of the corresponding actuator Correspnding actuators are shown below Spe Stroke options R...

Страница 11: ...ocking terminal Cable length I O cable 5m or less Actuator cable 20m or less Battery Nickel metal hydride battery 3 6V Customer should prepare a battery suitable for the controller Cooling method Air...

Страница 12: ...or more No Part name Remarks 1 Battery Nickel metal hydride battery equivalent to FDK HF 4 3FAUC 2 Connector with lead wire Connector Equivalent to JST PHR 3 Pin number No Name Wiring 1 Battery 2 Bat...

Страница 13: ...and connect the cable while the data is being written power supply LED green flashes Possibility of incorrect data step data parameter 2 ALM Power supply LED Red Power supply ON With alarm Solid red...

Страница 14: ...on Absolute error Red light on 11 STS2 Battery charge LED Fully charged 72 hours continuous charge Green light On Charging Orange light On Not connected including discharged state Red light On 12 Appl...

Страница 15: ...e front of the controller and the cover lid for connectors Leave the space between controllers so that the operating temperature of the controller stays within the specification range Avoid mounting o...

Страница 16: ...tor manually during back up make sure that the cycles of the motor is within the range of Maximum cycle of the motor when the power supply is cut If the motor rotation limit is exceeded or the backup...

Страница 17: ...to absolute controller Description Input range Content Controller Software Teaching box Sensor type Sensor type 1 2 1 Incremental Encoder signal is not backed up when the power supply is cut 2 Absolu...

Страница 18: ...s HOLD is ON and when HOLD is turned OFF the actuator restart to travel the remaining stroke When DRIVE or SETUP is ON Caution 1 As long as HOLD is ON the DRIVE input will be disabled 2 The output sig...

Страница 19: ...18 motor will be turned OFF...

Страница 20: ...uns over the defined pushing width these terminals will be turned OFF B2 OUT1 B3 OUT2 B4 OUT3 B5 OUT4 B6 OUT5 B7 BUSY This terminal is ON during the movement of the actuator during the positioning ope...

Страница 21: ...energy saving mode if the energy saving setting is less than the Trigger LV value the INP output signal will turn OFF When movement starts again from the pushing stopped state it will do pushing oper...

Страница 22: ...2 On completion of the positioning operation OFF ON 4 ON Release ON ON 2 Stopped due to pushing a work load in pushing operation OFF ON ON Release ON ON 2 Stopped due to no detection of work load duri...

Страница 23: ...er resetting the two alarms After purchase power is supplied for the first time with the electric actuator connected When the battery built in to the controller is replaced When the backup period has...

Страница 24: ...23 Caution When you wish to check the hold of the electric gripper please contact SMC...

Страница 25: ...on The time taken for SVRE output to turn on depends on the actuator type and the operating conditions Actuator with lock is unlocked 10 SETUP input turns on 11 BUSY output turns on Starts 12 SETON I...

Страница 26: ...ed Afterwards DRIVE etc is available T1 1 6s or less System initialize time Time required to activate alarm T4 3s or less System initialize time Time required to activate alarm Position data recovery...

Страница 27: ...Returning action is completed Afterwards DRIVE etc is available T1 1 6s or less System initialize time Time required to activate alarm T2 15ms or longer Recommendation 30ms RESET input SETUP input T3...

Страница 28: ...Starts 9 SETON INP output turns on Return to origin is completed when BUSY output is turned off Afterwards DRIVE etc is available Caution Alarm is generated twice when battery replacement is necessar...

Страница 29: ...28...

Страница 30: ...Actuator with lock is unlocked 5 SETUP input turns on 6 BUSY output turns on Starts 7 SETON INP output turns on Return to origin is completed when BUSY output is turned off Afterwards DRIVE etc is av...

Страница 31: ...rallel signal output ALARM OUT0 OUT1 OUT2 OUT3 Alarm group A OFF ON OFF OFF OFF Alarm group B OFF OFF ON OFF OFF Alarm group C OFF OFF OFF ON OFF Alarm group D OFF OFF OFF OFF ON Alarm group E OFF OFF...

Страница 32: ...tor manual or the catalog Please refer to the manual or the catalogue of the actuator for the maximum speed of the actuator System parameter is incorrect 1 049 System PARA incorrect B RESET Condition...

Страница 33: ...RESET Condition During pushing operation the actuator is pushed back from the start position of pushing Countermeasure Increase the distance from the pushing operation origin position to the object b...

Страница 34: ...the absolute circuit is not normal Countermeasure Check the operating environment if there is affect of noise Alarm_Com ment_107 1 107 Battery voltage reduce C Input RESET Condition The alarm is gene...

Страница 35: ...l or the catalogue of the actuator for the maximum speed of the actuator Controller temperature is out of the set value 1 146 Overheat D RESET Input SVON Condition Ambient temperature of the power ele...

Страница 36: ...after supplying power for 72 consecutive hours replace the battery Caution This alarm and related alarm battery voltage decrease alarm which caused the alarm to be generated Alarm_Com ment_153 1 153 A...

Страница 37: ...ountermeasure Absolute power suuply voltage fell below set value 1 156 Low AbPow Vol D RESET Input RESET SVON SETUP Condition Absolute power supply voltage fell below set value Countermeasure Even aft...

Страница 38: ...nsor failure E Cycle the power supply for the controller Condition An abnormality is detected in the current sensors which are recognized when the controller is initialized Countermeasure Make sure th...

Страница 39: ...th tap water and seek medical treatment Warning 1 Do not use battery when there is leakage discoloration or deformation Heating explosion or ignition of the battery can result 2 The battery contains a...

Страница 40: ...al power supply Alarm generated Controller alarm is generated Refer to the operation manual of the controller Check the type of alarm Take appropriate measures according to this manual Lock release er...

Страница 41: ...pushing operation the INP output signal is turning on On completion of pushing the operation the output INP signal is generated the PLC cannot confirm the completion of driving If the controller vers...

Страница 42: ...ctly Separate the power supply for the CN1controller power supply and the CN5 I O signal power supply Inappropriate specification Check if a product with a suitable specification was selected Reconfir...

Страница 43: ...ctor is turned OFF due to the temporary voltage drop of the power supply and the actuator stops The stopping condition is released by the voltage recovery Possibility of momentary voltage drop due to...

Страница 44: ...vision history No TQ0870054 OM002 First edition July 2012 No TQ0870054 OM004 Sep 2013 Revision LECPF LECP7 Note This manual is subject to change without prior notice 2013 SMC Corporation All Rights Re...

Отзывы: