- Mounting/Removal of the cartridge assembly and replacement of emitter
1. Ensure that the power supply and compressed air supply are disconnected before removing the
power cable.
2. Turn the locking knob of the cartridge assembly to the FREE position to release the lock.
(The locking knob cannot be rotated until the power cable is removed).
3. The cartridge assembly can be removed by pulling it in the direction of the arrow. Take care with the
emitter when pulling the cartridge assembly.
4. Hold the emitter assembly (which is mounted to the cartridge assembly) using tweezers and pull out
in the direction of the arrow. To avoid injury take care not to touch the very sharp emitter ends.
5. When mounting a new emitter assembly to the cartridge assembly, use gloves and tweezers to
ensure the emitter is not contaminated. (Do not touch the emitter assembly with bare hands).
6. The procedure for mounting the cartridge assembly is the reverse of removal.