4. Clean the emitter mounted to the cartridge assembly.
-
Cleaning of the emitter
-
Using the cleaning kit, saturate the felt with industrial alcohol, insert it into the emitters and rotate
several times to clean. If the dirt does not come off, use the rubber grindstone to clean the emitters in
the same way. After that, again use the felt saturated with industrial alcohol to finish the cleaning.
If a cleaning kit is not available, saturate a cotton swab with alcohol
Note 1)
to clean the emitters.
Note 1) The industrial alcohol used should be reagent ethanol class 1 99.5vol% or greater.
The cleaning kit has a felt pad and a rubber grindstone. Choose the felt pad or rubber grindstone
depending on the level of contamination to effectively clean the emitters.
5. The procedure for mounting the cartridge assembly is the reverse of removal. Confirm that the
locking knob is in the FREE position. The cartridge assembly cannot be inserted while the locking
knob is in the LOCK position, attempting to do so may cause damage.
4-3. Replacement of the emitter assembly
If the emitters are worn out or damaged, replace the emitter assembly.
Cleaning kit (IZS30-M2)
Felt
Rubber
grindstone
2 replacement felt pads
included
+
Rubber
grindstone
Felt
Use for normal
cleaning
Use if dirt cannot be
removed with felt.