Do not use a load which generates surge voltage.
When a surge-generating load such as a relay or solenoid is driven directly, use a Pressure switch with a built-in
surge absorbing element.
•
The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes
in the system.
•
Mount the product in a place that is not exposed to vibration or impact.
Otherwise failure or malfunction can result.
•
Prevent foreign matter such as remnant of wires from entering the Pressure switch.
Take proper measures for the remnant not to enter the Pressure switch in order to prevent failure or malfunction.
•
Do not use the product in an environment that is exposed to temperature cycle.
Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product.
•
Do not expose the product to direct sunlight.
If using in a location directly exposed to sunlight, shade the product from the sunlight.
Otherwise failure or malfunction can result.
•
Keep within the specified fluid and ambient temperatures range.
The fluid and ambient temperatures should be 0 to 50 °C. Operation under low temperature (5 °C or less) leads to
cause damage or operation failure due to frozen moist in the fluid or air.
Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water.
Avoid sudden temperature change even within specified temperature.
•
Do not operate close to a heat source, or in a location exposed to radiant heat.
Otherwise malfunction can result.
*Adjustment and Operation
•
Turn the power on after connecting a load.
Otherwise it can cause excess current causing instantaneous breakage of the Pressure switch.
•
Do not short-circuit the load.
Although error is displayed when the Pressure switch load is short circuit, generated excess current lead to cause
the damage of the Pressure switch.
•
Do not press the setting buttons with a sharp pointed object.
It may damage the setting buttons.
•
If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first.
There will be a drift on the display and the analog output of approximate
±
1% immediately after the power supply is
turned on, within 10 minutes.
•
Perform settings suitable for the operating conditions.
Incorrect setting can cause operation failure.
For details of each setting, refer to page 21 to 46 of this manual.
•
The Pressure switch is compulsory turned off for 4 seconds after power supplied.
For 4 seconds after supplying power, the measurement output is turned off.
•
Do not touch the LCD during operation.
The display can vary due to static electricity.
*Maintenance
•
Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
•
Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
•
Perform drainage regularly.
If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.
•
Do not use solvents such as benzene, thinner etc. to clean the Pressure switch.
They could damage the surface of the body and erase the markings on the body.
Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully
squeezed, then wipe up the stains again with a dry cloth.
Содержание ISE30A Series
Страница 1: ...No PS OML0003 B PRODUCT NAME Digital Pressure Switch MODEL Series Product Number ZSE30A F ISE30A ...
Страница 9: ... 8 No PS OML0003 B Model Identification and how to order ...
Страница 16: ... 15 No PS OML0003 B Bracket C Model ZS 38 A3 The bracket A B C can be mounted in 4 ways ...
Страница 62: ... 61 No PS OML0003 B Mounting by bracket Bracket A Bracket B ...
Страница 63: ... 62 No PS OML0003 B Bracket C ...
Страница 64: ... 63 No PS OML0003 B Mounting by panel mount adapter Mounting by panel mount adapter Front protective cover ...
Страница 65: ... 64 No PS OML0003 B Panel cutout dimension ...