Other Settings
○
Peak/Bottom hold value indication
The maximum (minimum) pressure from when the power is supplied to this moment is detected and
updated. In peak/bottom indication mode, the pressure is indicated.
As the peak indication, when the
button is pressed for 1 second or longer, the maximum pressure and
"Hi" starts flashing, and is held.
To release holding the indication of the maximum pressure, press the
button for 1 second or longer
again. The measurement mode returns.
As the bottom indication, when the
button is pressed for 1 second or longer, the minimum pressure
and "Lo" starts flashing and is held.
To release holding the indication of the minimum pressure, press the
button for 1 second or longer
again. The measurement mode returns.
If the
and
buttons are pressed simultaneously for 1 second or longer while the pressure is being
held, the maximum (minimum) value is cleared.
○
Zero clear
A displayed value can be adjusted to zero when the pressure to be measured is within
±
7%F.S. (
±
3.5%F.S.
for compound pressure) of the pressure at the time of shipment from the factory.
(The range of
±
1%F.S. setting is different depending on the individual product difference)
Press continuously the
and
buttons for 1 second or longer simultaneously, display is cleared as "0".
Return to the measurement mode automatically.
○
Key lock
A wrong operation performed unintentionally such as change of set value can be prevented.
If the button operation is performed while key lock setting is being performed, "LoC" is displayed for
approximate 1 second.
(When the
button is pressed, the set pressure is displayed following "LoC".)
<Operation -Without security code input- >
1, Keep pressing the
button for 5 seconds or longer in measurement mode.
The current setting "LoC" or "UnL" is displayed.
(Releasing key lock can be done in the same way.)
2, Press the
or
button to select locking or unlocking of the key.
3, Press the
button to enter the setting.
Содержание ISE30A Series
Страница 1: ...No PS OML0003 B PRODUCT NAME Digital Pressure Switch MODEL Series Product Number ZSE30A F ISE30A ...
Страница 9: ... 8 No PS OML0003 B Model Identification and how to order ...
Страница 16: ... 15 No PS OML0003 B Bracket C Model ZS 38 A3 The bracket A B C can be mounted in 4 ways ...
Страница 62: ... 61 No PS OML0003 B Mounting by bracket Bracket A Bracket B ...
Страница 63: ... 62 No PS OML0003 B Bracket C ...
Страница 64: ... 63 No PS OML0003 B Mounting by panel mount adapter Mounting by panel mount adapter Front protective cover ...
Страница 65: ... 64 No PS OML0003 B Panel cutout dimension ...