No.DIG-31900-OM002
30
■
Parameter Code Detail
(000) Actuator type
(200) Operation direction
setting
Displays “rotary (rtry)”. This parameter is fixed when shipped, and
cannot be modified.
“Direct
*
3
(dir)” or “Reverse
*
4
(rvS)” can be selected. The default
when shipped is “direct (dir)”.
When the operation direction is modified, it is reflected on each
item in accordance with Table 9.
0%
100%
0%
100%
200=dir
200=rvS
0%
100%
S
tro
k
e
Input current
Fig. 24
3:
Direct direction means an actuator’s operation direction which is
determined by air output from “OUT 1” port on the positioner’s body.
4:
Reverse direction means an actuator’s operation direction which is
d
etermined by air output from “OUT 2” port on the positioner’s body.
Table 9
Operation
direction
Input
current
Input
value
(S value)
Position
value
(P value)
Actuator
opening
Analog
output
(mADC)
(
%
)
(
%
)
(degree)
(mADC)
Direct
(dir)
4-20
0-100
0-100
0-90
4-20
Reverse
(rvS)
4-20
0-100
100-0
90-0
20-4
Содержание IP8101 Series
Страница 1: ...No DIG 31900 OM002 H SMART POSITIONER ROTARY TYPE PRODUCT NAME IP8101 Series MODEL Series...
Страница 15: ...No DIG 31900 OM002 14 Table 6 Piping Layout...
Страница 75: ...No DIG 31900 OM002 74 Drawing...
Страница 76: ...No DIG 31900 OM002 75...
Страница 77: ...No DIG 31900 OM002 76...
Страница 78: ...No DIG 31900 OM002 77...
Страница 79: ...No DIG 31900 OM002 78...
Страница 80: ...No DIG 31900 OM002 79...
Страница 81: ...No DIG 31900 OM002 80...
Страница 82: ...No DIG 31900 OM002 81...
Страница 83: ...No DIG 31900 OM002 82...
Страница 84: ...No DIG 31900 OM002 83...