Principles of Operation: 

The Apex 7000 positioner causes rotation (or linear movement) of valve actuator in proportion to an input signal. This 
signal may take the form of pneumatic pressure (Model 7000 and 7600) or electric current (Models 7100,7200 7400 
7500). Supply pressure is directed to the actuator through a precision spool valve. As input pressure is varied, the 
balance beam shifts away from its neutral position. The spool also shifts and a differential pressure is created across 
the actuator causing rotation (or linear movement). Actuator motion is fed back through the positioner shaft and cam. 
Cam rotation causes movement of the feedback arm, changing compression in the feedback spring, forcing the 
balance beam and spool back to their neutral position. This shuts off the flow of air to the actuator and rotation stops

.  

 

Installation: 

The Apex 7000 positioner can be installed on rotary and linear actuators. Actuators can be either double acting or 
spring return. Positioners can be set up for rotation in either direction ( direct or reverse acting). 
 

Supply Air Requirements: 

Air pressure must be limited to 150 psi for supply and 30 psi for instrument signal to avoid damage to the positioner. 
Supply air must be clean, dry and oil free instrument quality air in accordance with ISA S7.3 specifications ( dew point 
>18 degrees below ambient temperature, particle size <5 microns, oil content <1ppm. 
 

Mounting: 

The following instructions apply to rotary actuators only. Linear applications require special mounting and coupling 
(consult factory). 
 

1.  Mount bracket to actuator. Tighten bolts finger tight only at this time. A standard bracket is available for 

mounting to NAMUR compliant actuators.  

 

2.  Install coupler (not required if installing to a NAMUR compliant actuator) on actuator shaft making sure it is 

centered.  

 

3.  Verify that orientation of actuator ( and coupler ) flats match positioner shaft flats. If necessary, rotate the cam 

before installing positioner ( see “Cam Installation”).  

NOTE: Actuator should be in orientation corresponding to 

zero input signal.

  

 

4.  Install positioner onto bracket. Make sure positioner shaft and coupler are engaged and centered. Tighten bolts 

finger tight only at this time.  

Pneumatic Connections: 

All pneumatic connections, the supply, both output ports, and instrument ports are 

female ¼” NPT. All connections require user-supplied tubing fittings. 

Caution:

 

Do not use Teflon tape as a pipe 

thread sealant. Use only a liquid or paste non-hardening pipe sealant on the threads.  

 

  5. Connect positioner ports C1 and C2 to actuator. Port C2 is 

always

 connected to the actuator port used to drive 

actuator away from its start or fail position ( the factor cam setting is full clockwise at minimum input ). Port C1 is 
connected to the opposite port or may be plugged for spring return actuators. 

Note:  For fail counterclockwise 

applications, the cam must be flipped over so the “R” side is facing upwards (see “Cam Installation”). 

  
 

Содержание APEX 7000

Страница 1: ...cations dew point 18 degrees below ambient temperature particle size 5 microns oil content 1ppm Mounting The following instructions apply to rotary actuators only Linear applications require special m...

Страница 2: ...e made to the valve closed position Always start calibration procedure by applying 0 input signal then adjusting zero position Caution Cam pinch points may injure fingers Be sure to avoid placing fing...

Страница 3: ...etting by turning screw C while doing so keep the zero screw B in position by applying pressure with your thumb 8 Lock the calibration mechanism in place by tightening locking screw A 9 Apply 0 signal...

Страница 4: ...w Figure below shows cam setting for Direct Action increasing signal 0 1005 20 100 kPa 3 15 psi to open Cam follower to ride on lobe D 0 100 Figure below shows cam setting for reverse action decreasin...

Страница 5: ...nce arm 5 engage the slot in spool 6 3 Tighten screw 1 4 Check for smooth operation of assembly I P Installation All I O modules are factory calibrated an cannot be adjusted Kits are available to allo...

Страница 6: ...es 1 See hazardous location certificate for detailed temperature ratings All Apex 7000 units comply with ATEX directive for non electric equipment intended for use in hazardous locations to Ex II 2 G...

Страница 7: ...equipment See Supply Air Requirements 2 Make sure arms bearings and adjustment screws move freely Caution Moving parts to check freedom with supply pressure connected will cause rotation of cam Be sur...

Страница 8: ...y 7 1 Feedback spring 6 30 psi assembly Green 8 1 Lower arm assembly 9 1 Rod 10 1 Spring 11 1 Twist Stop 12 1 Pilot valve incl O rings 13 1 Cam locking nut incl screw 15 1 Mounting adapter incl screws...

Страница 9: ...necting block NPT assembly 3 1 Connecting block G assembly 4 1 Relief valve spring 6 1 Gasket for Apex 7000 6 1 Gasket for Apex 7100 7 1 Diaphragm cover incl O ring 8 1 Diaphragm 9 2 Diaphragm washer...

Страница 10: ...PT 1 8 36 4 Plug 1 8 G 37 1 Cam 38 45 75 80 1 Screw set Apex 7000 7100 6 46 53 67 70 75 80 1 O ring set Apex 7000 7100 Nitrile NBR 6 46 53 67 70 75 80 1 O ring set Apex 7000 7100 Silicone Q 54 1 Spind...

Страница 11: ...purchaser user must therefore assume the ultimate responsibility for the proper sizing and selection installation operation and maintenance of Flowserve products The purchaser user should read and und...

Отзывы: