background image

The  six  and  seven  position  cylinders  are  medium  duty  pneumatic 
positioning devices that operate through six or seven predetermined 
positions of ½” (12.7 mm) increments with total strokes of 2½” (63.5 
mm) or 3” (76.2 mm) respectively.  They were primarily designed for 
power-shift transmissions but may also  be utilized for indexing  and 
any  other  application  where  fixed  stroke  increments  are  required.  
The  ideal  companion  valve  for  these  cylinders  is  Type  "P"  six  or 
seven  position  Rotair®  Valve.    An  alternative  control  is  an  electro-
pneumatic  switching  circuit  using  3-way  solenoid  valves.    These 
cylinders are extremely rugged having anodized, corrosion resistant, 
lightweight aluminum body, pistons and pistons stops. 

 

WARNING: INSTALLATION AND 
MOUNTING 

 

The user of these devices must conform to all applicable electrical, 
mechanical,  piping  and  other  codes  in  the  installation,  operation  or 
repair of these devices. 
 

INSTALLATION!

  Do  not  attempt  to  install,  operate  or  repair  these 

devices  without  proper  training  in  the  technique  of  working  on 
pneumatic  or  hydraulic  systems  and  devices,  unless  under  trained 
supervision. 
Compressed air and hydraulic systems contain high levels of stored 
energy.  Do  not  attempt  to  connect,  disconnect  or  repair  these 
products when a system is under pressure. Always exhaust or drain 
the  pressure  from  a  system  before  performing  any  service  work. 
Failure to do so can result in serious personal injury. 
 

MOUNTING!

 Devices should be mounted and positioned in such a 

manner that they cannot be accidentally operated. 
 

INSTALLATION 

 

Mount  the  cylinders  in  any  desirable  plane  to  a  sturdy,  flat  surface 
(preferably  with  the  ports  facing  down)  with  three  3/8"  bolts. 
Mounting  lugs  are  cast  in  the  body  of  the  cylinders.  Avoid 
misalignment  with  the  load  to  be  positioned  since  side  thrust  and 
binding will affect the service life of the rod bearing and piston stop 
seals.  
 
All  ports  are  1/4”-18  NPT.  The  following  ports  should  be  piped 
together with "T" connections: 3 with 3A on the six position cylinder, 
3 with 3A and 6 with 6A on the seven position cylinder.  Connections 
should  be  made  as  close  to  the  cylinder  as  possible  to  reduce  the 
number of lines from the control valve.  
 

OPERATION 

 

Maximum  operating  pressure  is  150  psi  (10  bar)  within  a 
temperature  range  of  -40°

 

to  200°F  (-40°  to  93°C).  The  cylinder 

piston  rod  reaches  its  various  positions  in  response  to  pressure 
being supplied to the cylinder ports as shown in the truth tables on 

pages  3  and  5.  V  means  air  must  be  vented  to  atmosphere,  S 
means air must be supplied and S/V means port can be supplied or 
vented.  whichever  is  most  convenient  in  the  control  valve.  Each 
cylinder has reverse at full extended position of the rod and is spring 
returned to neutral (next position in from reverse) from any position. 
The transmissions which these cylinders usually control have the full 
automatic  or  drive  position  adjacent  to  neutral.  The  corresponding 
position is 5 on the seven position and 4 on the six position cylinder. 
The  sequential  order  of  cylinder  positions  is  a  function  of  the  "P" 
Rotair Valve. 
 
The  forces  developed  by  the  cylinder  are  functions  of  the  air 
pressure applied to the exposed piston areas and are tabulated for 
rod  movement  to  the  various  stroke  positions  as  shown  on  the 
charts on pages 6 and 7. 
The internal spring returns the piston rod to its Neutral position when 
air  pressure  is  intentionally  or  unintentionally  exhausted  from  all 
control lines.  This safety feature returns the transmission to neutral 
if the air supply is lost. 
 

MAINTENANCE 

 

Periodically  disassemble  the  cylinder  for  cleaning  and  inspection.  
Clean  all  metal  parts  with  a  nonflammable  solvent  and  wash  all 
rubber parts with soap and water.  Rinse thoroughly and dry, using 
low pressure jet, if available.  Replace all damaged or worn parts. 
Reassemble the cylinder, lubricating each part as it is put in place.  
Rubber  parts  should  be  lubricated  with  Dow  Corning  No.  55 
pneumatic grease.  Check the operation of the reassembled cylinder 
by putting low pressure air in the ports in accordance with the truth 
table, pages 3 and 5. 

 

NOTE

:   

When disassembling a cylinder, please use CAUTION as 

the return springs are under compression. 
 

ADJUSTMENT 

 

AVENTICS 

six and seven positions require no adjustment.  

SIX  R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) 

POSITION CYLINDERS 

Service Information 

SM-1000.4905 

NOTE:   

“P”  Rotair  Valve  R431006324  (P  -063984-00000)  was  designed  to  control 
six position cylinder R431006322 (P-063982-00001) and valve R431006326 
(P  -063985-00000)  was  designed  to  control  seven  position  cylinder 
R431006321  (P  -063981-00002).    Both  of  these  Rotair  Valves  have  first 
gear  position adjacent to neutral and  progress  toward full automatic  at  the 
extreme position of valve handle travel Rotair Valves can be made available 
to  have  the  handle  position  sequence  identical  to  the  transmission.    Six 
position  Rotair  R431006324  (P  -063984-00000)  should  be  connected  as 
follows: 
Ports  No.  1  and  No.  5  plugged,  Exhaust  port  is  1/8”  NPT,  pressure  is 
supplied to unnumbered port in the side of the pipe bracket, valve port No. 2 
to cylinder port No. 2, valve No. 4 to cylinder No. 5, valve No. 3 to cylinder 
No.  3  &  3a,  and  valve  port  No.  6  to  cylinder  port  No.  6A  in  six  position 
cylinder R431006322 (P -063982-00001).  
Seven position Rotair R431006326 (P -063985-00000) should be connected 
as follows:  port No. 1 plugged, exhaust port No. 4, pressure is supplied to 
unnumbered port in  the side of the pipe bracket, valve port No. 2 to cylinder 
port No. 2, valve No. 5 to cylinder No. 5, valve No. 3 to cylinder No. 3 & No. 
3A  and  valve  port  No.  6  to  cylinder  No.  6  &  6A  in  seven  position  cylinder 
R431006321 (P -063981-00002). 

Отзывы: