IDX-OM-V022
Chapter 5 Maintenance
5.2
Periodical Maintenance
IDF60/70/80/90 Series
5-2
5.2 Periodical Maintenance
5.2.1
Cleaning of dust proof filter
Clean dust and other foreign particles from the dust proof filter with vacuum cleaner or air blow nozzle
once a month.
5.2.2
Cleaning of Auto Drain
Remove the dust deposited in the auto drain
element
every month. Use neutral detergent for cleaning.
If they are too dirty, replace them and shorten the period of maintenance from next time.
(1)
Removal of the case assembly
1) Turn off the switch with lamp.
2) Shut off the earth leakage breaker of the power supply or remove the power supply plug from
the socket.
3) Fully close the valve at the compressed air IN and OUT piping. (Open the bypass valve, only
when compressed air is required during maintenance.)
4) Close the ball valve on the top of the auto drain.
5) Remove the drain tube.
6) Remove the clip and rotate the drain cock to "O" side to release the residual air pressure in the
auto drain.
During air blowing, put on protective glass and mask to prevent dusts from coming
into throat or eyes.
CAUTION
- Be sure to release the residual pressure of the auto drain before starting
maintenance.
- If the bowl assembly is damaged or contaminated, replace it with a new one.
WARNING
Ball valve: Close
Remove the clip
Drain cock
“O”: Open
Содержание IDF60-20-C