IDX-OM-V022
Chapter 11 Specification for Option T
IDF60/70/80/90 Series
11.4 How to connect the power supply and signal cable
11-3
11.4 How to connect the power supply and signal
cable
Connect the power cable and signal cable in the following procedures.
1) Remove the front panel.
2) Insert the power cable prepared by the customer into the power cable inlet (with strain relief) then
connect the power cable to the terminal.
3) Insert the signal cable prepared by the customer into the signal cable inlet (with rubber grommet) then
connect the signal cable to the each terminal.
M3.5 screw tightening torque: 1.0 to 1.3Nm
M4 screw tightening torque: 1.4 to 2.0Nm
During wiring work, do not touch other sections except terminal block.
4) Replace the front panel.
Front panel
Rubber grommet
Signal cable entry
Strain relief
Power cable entry
Customer connection side
1 2 3
PE
N
L
6
5
4
7
IDF60-20-T, IDF70-20-T
IDF80-20-T, IDF90-20-T
Terminal connecting screw: M3.5
Crimping terminal width: 8.5mm and below
Applicable electrical wire: 1.25mm
2
or more
Terminal connecting screw: M4.0
Crimping terminal width: 9.5mm and below
Applicable electrical wire: 2.0mm
2
or more