HRX-MM-N007
Chapter 4 Service Procedure
HRS Series
4.5 Replacement Procedure
4-43
Mounting
1.
Mount the inlet socket. (Screw ×2)
Be careful of the mounting direction.
Fig. 4.5-29 Mounting direction in inlet socket
2.
Mount the plate. (screw ×4)
3.
Insert wiring to terminal A-
A’, B-B’, [G1] to terminal C, [LOAD] to terminal D.
Fig. 4.5-30 Entry of connector
4.
Mount the upper panel and the side panel on the right in reversed order of removal.
Inlet socket
Power switch
Содержание HRS012-A*-10-*
Страница 16: ...HRX MM N007 Chapter 2 Name of Parts 2 2 Component Parts HRS Series 2 4...
Страница 136: ...HRX MM N007 Chapter 3 Alarm Indication and Troubleshooting 3 3 Troubleshooting HRS Series 3 120...
Страница 200: ...HRX MM N007 Chapter 4 Service Procedure 4 5 Replacement Procedure HRS Series 4 64...
Страница 220: ...HRX MM N007 Chapter 6 Documents 6 4 Flow chart HRS Series 6 8...