HRX-MM-N007
Chapter 4 Service Procedure
4.5 Replacement Procedure
HRS Series
4-22
2.
Mount the pump. (Screw ×4)
3.
Mount the hose. (2 pcs.)
Tightening torque of hose between high pressure pump and circulating fluid outlet
:
4.
Connect the ground cable (G4). (Screw ×1)
5.
Mount cable to the condenser.
6.
Mount pump cable to the power board.
For the HRS030, fix the pump cable on the fan motor bracket with a cable tie to prevent
the pump cable from touching the fan.
7.
Mount the support panel. (Screw ×2)
8.
Mount the upper panel and the right panel in reversed order of removal.
Содержание HRS012-A*-10-*
Страница 16: ...HRX MM N007 Chapter 2 Name of Parts 2 2 Component Parts HRS Series 2 4...
Страница 136: ...HRX MM N007 Chapter 3 Alarm Indication and Troubleshooting 3 3 Troubleshooting HRS Series 3 120...
Страница 200: ...HRX MM N007 Chapter 4 Service Procedure 4 5 Replacement Procedure HRS Series 4 64...
Страница 220: ...HRX MM N007 Chapter 6 Documents 6 4 Flow chart HRS Series 6 8...