15-
3.4.
Vendor defined parameters
Tale 3-8. Vendor defined parameters
Index(dec) Subindex Access
Parameter name
Size[byte] Data Storage Section
0x0040(64)
1...16
R/W Pressure P1
2
Y
0x0041(65)
1...16
R/W Hysteresis H1
2
Y
0x0042(66)
1...16
R/W Pressure P2
2
Y
0x0043(67)
1...16
R/W Hysteresis H2
2
Y
0x0044(68)
1...16
R/W Pressure P3
2
Y
0x0045(69)
1...16
R/W Hysteresis H3
2
Y
0x0046(70)
1...16
R/W Pressure sensor use
1
Y
0x0047(71)
1...16
R/W Supply valve type
1
Y
0x0048(72)
1...16
R/W Energy saving function
1
Y
0x0049(73)
1...16
R/W Pressure range
1
Y
0x004A(74)
1...16
R/W Valve protection count
1
Y
0x0055(85)
1...16
R
Current pressure value
2
N
0x0056(86)
1...16
R
Valve short circuit status
1
N
0x0057(87)
1...16
R
Pressure sensor
failure/disconnection status
1
N
0x0058(88)
1...16
R
Valve protection status
1
N
0x0059(89)
1...16
R
Supply valve type status
1
N
0x005A(90)
1...16
R
Pressure/Hysteresis parameter
failure status
1
N
0x005B(91)
0
R
Receive error count
4
N
0x0091(145)
0
W
Zero clear
1
N
0x0092(146)
0
W
Valve protection release
1
N
Note
"Y" means included in DataStorage, "N" means not included in DataStorage.
Parameter settings should be carried out with all ejector CHs in the following state :
-
Supply valves closed (vacuum instruction OFF)
-
Release valves closed (release instruction OFF)
-
Atmospheric open state with no pressure applied in the ejector
Refer to
For parameters of Index 64...74, 85...90 :
Parameter for each ejector CHs can be access individually by specifying the relevant Subindex.
i.e., CH0 parameters are accessed via Subindex 1, CH1 via Subindex 2 etc.
Subindex 0 can be used to access all CH parameters at once.
i.e., disables the energy saving function for all CHs by writing 0 to Index 72 and Subindex 0.