18-
3.4.8.
Supply valve type (Index 71)
Table 3-16. Supply valve type
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R/W
0x01 Supply valve type of CH0
Set the N.O./N.C. of the supply valve type for
each CH.
0x00 : N.C.
0x01 : N.O.
...
...
...
...
...
16
1
R/W
0x01 Supply valve type of CH15
Note
The setting must match the supply valve type fitted in vacuum manifold.
Diagnostic information will be issued when a supply valve type mismatch is detected.
Refer to
and
3.4.9.
Energy saving function (Index 72)
Table 3-17. Energy saving function
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R/W 0x01
Enable/Disable energy
saving function of CH0
Set Enable/Disable energy saving function for
each CH. Refer to
0x00 : Disable
0x01 : Enable
...
...
...
...
...
16
1
R/W 0x01
Enable/Disable energy
saving function of CH15
3.4.10.
Pressure range (Index 73)
Table 3-18. Pressure range
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R/W
0x01
Rated pressure range of pressure
sensor of CH0
Set rated pressure range of pressure
sensor to be used in each CH.
0x00 : -100...200 kPa
0x01 : -100...100 kPa
...
...
...
...
...
16
1
R/W
0x01
Rated pressure range of pressure
sensor of CH15
Note
The setting must match the rated pressure range of sensor fitted in vacuum manifold.