20-
3.4.14.
Pressure sensor failure/disconnection status (Index 87)
Table 3-22. Pressure sensor failure/disconnection status
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R
0x00
Pressure sensor
failure/disconnection status of CH0
Read pressure sensor
failure/disconnection status for each CH.
0x00 : No failure/disconnection
0x01 : Failure/Disconnection detected
Fixed at 0x00 for CHs whose Pressure
sensor parameter is set to Unused.
...
...
...
...
...
16
1
R
0x00
Pressure sensor
failure/disconnection status of CH15
3.4.15.
Valve protection status (Index 88)
Table 3-23. Valve protection status
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R
0x00
Valve protection status of
CH0
Read valve protection function status of each CH.
0x00 : No valve protection operation
0x01 : Valve protection operating
Fixed at 0x00 for CHs whose parameter setting apply
following conditions :
-
Pressure sensor use parameter is set to Unused
-
Energy saving function parameter is set to Disable
...
...
...
...
...
16
1
R
0x00
Valve protection status of
CH15
3.4.16.
Supply valve type status (Index 89)
Table 3-24. Supply valve type status
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R
0x00
Supply valve type
mismatch status of CH0
Read supply valve type mismatch status for each CH.
0x00 : No mismatch
0x01 : Mismatch detected
Fixed at 0x00 for CHs whose Pressure sensor
parameter is set to Unused.
...
...
...
...
...
16
1
R
0x00
Supply valve type
mismatch status of CH15
3.4.17.
Pressure/Hysteresis parameter failure status (Index 90)
Table 3-25. Pressure/Hysteresis parameter failure status
Sub
index
Size
[byte]
Acc
ess
Default
Content
Description
1
1
R
0x00
Pressure/Hysteresis parameter
failure status of CH0
Read Pressure/Hysteresis parameter setting
failure status for each CH.
0x00 : No setting failure
0x01 : Setting failure detected
Fixed at 0x00 for CHs whose Pressure sensor
parameter is set to Unused.
...
...
...
...
...
16
1
R
0x00
Pressure/Hysteresis parameter
failure status of CH15