28-
5.
Example of energy saving operation of ejector
Vacuum
instruction
ON
OFF
Positive pressure
Atmospheric
pressure
Time
Vacuum
confirmation
bit
1
0
Release
confirmation
bit
1
0
Negative pressure
Supply
valve
Open
Closed
Release
instruction
ON
OFF
Release
Valve
Open
Closed
(1)
(2)
(3)
(4)
(5)
H3
P3
H1
P1
P2
H2
Pressure of
release
confirmation
Pressure of
vacuum
confirmation
Energy saving
function
Fig 5-1. Sample of ejector operation
(1)When the vacuum instruction is ON, the supply valve is automatically closed when the
vacuum pressure reaches P2.
(2)When the vacuum pressure drops by P2-H2, the supply valve is automatically opened again.
(3)Repeat steps (1) and (2) unless the valve protection function is activated.
(4)The vacuum confirmation bit is set to 1 until the vacuum pressure reaches P1
and then drops to P1-H1.
(5)The release confirmation bit is set to 1 until the release pressure reaches P3
and then drops to P3-H3.