21-
3.4.18.
Receive error count (Index 91)
Table 3-26. Receive error count
Subindex Size[byte] Access
Default
Content
Description
0
4
R
0x00000000
Error count value of
IO-Link received data
Counts parity errors and checksum errors
in IO-Link communications.
The count is reset to 0 when the power
supply for logic/input switched OFF.
3.4.19.
Zero clear (Index 145)
Table 3-27. Zero clear
Subindex Size[byte] Access Default Content
Description
0
1
W
0x00
Zero clear
command
Adjust pressure value to 0 kPa at atmospheric pressure.
0x00 : No zero clear request
0x01 : Zero clear request
0x02 : Zero clear correction value reset request
Note
Zero clear and zero clear correction value reset are carried out in batches for all CHs.
Zero clear request and zero clear reset request are only processed when the write value changes
from 0x00 to 0x01 or 0x00 to 0x02. For this reason, write 0x00 once for the second and
subsequent request.
3.4.20.
Valve protection release (Index 146)
Table 3-28. Valve protection release
Subindex Size[byte] Access Default
Content
Description
0
1
W
0x00
Valve protection
release command
Release of valve protection function and resume
energy saving function. Refer to
0x00 : No valve protection release request
0x01 : Valve protection release request
Note
Valve protection release is carried out in batches for all CHs.
Valve protection release request is only processed when the write value changes from 0x00 to
0x01. For this reason, write 0x00 once for the second and subsequent request.