lldp medFastStartCount
This command specifies the amount of MED Fast Start LLDPDUs to transmit during
the activation process of the LLDP-MED Fast Start mechanism.
Syntax
lldp medfaststartcount
packets
seconds
- Amount of packets. (Range: 1-10 packets; Default: 4 packets)
Default Setting
4 packets
Command Mode
Global Configuration
Command Usage
The MEDFastStartCount parameter is part of the timer which ensures that the
LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Start
is critical to the timely startup of LLDP, and therefore integral to the rapid
availability of Emergency Call Service.
Example
lldp notification-interval
This command configures the allowed interval for sending SNMP notifications about
LLDP MIB changes. Use the
no
form to restore the default setting.
Syntax
lldp notification-interval
seconds
no lldp notification-interval
seconds
- Specifies the periodic interval at which SNMP notifications are
sent. (Range: 5 - 3600 seconds)
Default Setting
5 seconds
Command Mode
Global Configuration
Command Usage
• This parameter only applies to SNMP applications which use data stored in
the LLDP MIB for network monitoring or management.
• Information about changes in LLDP neighbors that occur between SNMP
notifications is not transmitted. Only state changes that exist at the time of a
Console(config)#lldp medfaststartcount 6
Console(config)#
Содержание 6152PL2 FICHE
Страница 2: ......
Страница 6: ...vi ...
Страница 8: ...viii ...
Страница 32: ...Tables xxxii ...
Страница 38: ...Figures xxxviii ...
Страница 56: ...Initial Configuration 2 10 2 ...
Страница 378: ...Configuring the Switch 3 322 3 ...
Страница 651: ...Address Table Commands 4 273 4 Example Console show mac address table aging time Aging time 100 sec Console ...
Страница 817: ......
Страница 818: ...SMC6128PL2 SMC6152PL2 149100000007A R01 ...