ALC404 LIGHTING TOWER CONTROLLER USER MANUAL
ALC404 Lighting Tower Controller 2018-11-06 Version 1.1 Page 69 of 83
8 PARAMETERS SETTING
8.1
SETTING MENU DESCRIPTION
Start the controller, then press
to enter into the parameters setting menu, menu items are as follows:
Return
Set Parameters
Time Calibration
Language Select
Event Log
Information
Users can jump to parameter setting, time calibration, language selection, event log, information query
and other screens.
8.2
PARAMETERS SETTING
When entered password interface, inputting ―00318‖ can set all parameter items in table
7.1 AUTO
START PARAMETER SETTINGS
and
table
7.2 GENERIC PARAMETER SETTINGS.
If the password is
changed only in
put the password same as controllers’, can the parameter be set via PC software. If there is
need to set more parameters or password is forgotten, please contact the factory.
NOTES:
a) Please change the controller parameters when generator is in standby mode (e. g. Crank disconnect conditions
selection, digital inputs, relay outputs, various delays), otherwise, shutdown and other abnormal conditions may
occurs.
b) Over voltage set value must be higher than under voltage set value, otherwise over voltage and under voltage
condition may occur simultaneously.
c) Over speed set value must be higher than under speed set value, otherwise over speed and under speed
condition may occur simultaneously.
d) Please set the generator frequency value as low as possible when cranking, in order to make the starter be
separated quickly as soon as possible.
e) Auxiliary input 1~7 cannot set as same items; otherwise, there are abnormal functions. However, the auxiliary
output 1~6 can be set as same items.
f) Flexible sensor 1~3 can be configured as temperature sensor, pressure sensor or fuel level sensor.
Simultaneously, sensors must connect to related coolant temperature, oil pressure and fuel level display on the
mains screen (when EFI engine set is controlled, only fuel level display is connected).
8.3
CONTROLLER TIME CALIBRATION
Table 30
– Time Calibration Process
No.
Operation Process
Panel Display
1
After controller power on, press
, then select
Time
Calibration,
press
again to the Date and Time Setting
interface. The date and time displayed will be stopped and
digital that highlight with black is currently adaptable for user
Time Calibration
Current Time
2017-12-04 (1) 08:27:55