ALC404 LIGHTING TOWER CONTROLLER USER MANUAL
ALC404 Lighting Tower Controller 2018-11-06 Version 1.1 Page 36 of 83
Category
Parameters
Range
Default
Description
as 0, it is time from ETS
solenoid hold expired to
genset stop completely;
Audible Alarm Time
(1~3600)s
30
It is audible alarm output
time after the new alarm
signal occurred.
Lights On Interval
(1~300)s
2
It is time from lights of
genset receive the turn
on/off signals to actually
turn on/off.
Rise Speed Pulse Time
(0.1~30.0)s
0.1
It is rise speed pulse output
time (output port configured
as Rise Speed Pulse)
Drop Speed Pulse Time
(0.1~30.0)s
0.1
It is drop speed pulse
output time (output port
configured as Drop Speed
Pulse)
Engine
Engine Type
(00~39)
00
Conventional
Engine
Default as conventional
engine.
When connect to J1939
engine, please select the
corresponding engine
model.
SPN Version
(1~3)
Version 1
Version 1
Version 2
Version 3
Flywheel Teeth
(10.0~300.0)
118.0
Flywheel teeth that installed
on the engine, which is
used for judging starter
disconnect conditions and
testing engine speed.
Details to see the following
installation instruction.
Speed On Load
(0-100)%
90
The setting value is rated
speed percentage, and
controller detects while
genset in ready for load
stage. If speed bellows
loading speed, genset will
not enter into normal
running stage.
Rated Speed
(0~5999)r/min
1500
Provide standard for
judging over /under speed