1.0 INTRODUCTION

The multi-purpose, TL-2015R2 central monitor can operate in small stand-alone call bell systems, or can be 
the heart of an extensive Smart wireless or cabled alert system. Ease of installation, simplicity of operation and 
economy are the main system features.  

Systems having multiple TL-2015R2 with external ield receivers can cover other areas/loors of buildings and up 
to ten (10) TL-2015R2 central monitors can be employed in one area, or site.

The TL-2015R2 central monitor combines with our TL-3004SYSR1, TL-3005SYSR1 door monitoring and Bed/
Chair CordLess

®

 monitoring systems, wristband wireless transmitters, nurse call buttons and other Smart 

wireless products, to provide indication and display of alert calls. It is a “supervised” system, automatically 
detecting equipment faults on various products, which are identiied and displayed on the front panel LCD.  

An interface unit is available for expansion of this central monitor to cover larger installations and standard, pre-
prepared interconnection cables are supplied that simply plug in to complete the system.  This interface/junction 
(CMJ-01) unit can integrate one internal and up to ive (5) external ield data receivers (CMRX-01).

This latest version can respond to “emergency” calls from ield equipment by providing different sound and 
display indications. 

In addition, a stand-alone wireless transponder (repeater unit: WBUM-02) is available that can substantially 
increase the distance at which the TL-2015R2 can operate with our other wireless transmitter products. The 
repeater does not apply to the cordless pads but these devices do have extended range of up to 200M. All other 
devices will work with the repeater.

2.0 SETTING UP AND INSTALLING THE TL-2015R2

Please refer to drawings 1, 2 and 3.  First adjust the controls to the required settings.  Various controls will be 
found in the rear panel of the unit.

With the OORC switch “off” (in the rear of the unit) the central monitor “memory” will be cleared of any previously 
stored fault detection codes.  Please refer to section 2.1.2 (a) Out of Range Check and 7.3.2 Field unit fault 
detected (b), below.

2.1 User selectable controls

2.1.1   Reset functions

A two-way switch is provided at the rear of the unit on the left hand side as you view the back for selection of 
user preferred Reset function.  

If the “MAG RST” option is selected, the user needs to present the 

Caregiver Key

 (CK-01) as proximity reset 

device at the point on the unit front panel (marked with a circle and labeled “Key”).  If the “BUT RST” option is 
selected, the user simply presses the Reset button (Acknowledge Button) mounted on the front panel of the unit.  
When the “MAG RST” option is selected, the front panel Reset button is disabled.

Содержание TL-2015R2

Страница 1: ...nd Nurse Call Paging System InstallationandUseInstructions 433 PGD Caegiver Pocket Pager with LCD Display 433 NC Wireless Nurse Call Button Optional Accessories SMART CAREGIVER C O RPO RAT I O N Tel 8...

Страница 2: ...2 Large Facility Central Monitor TL 2015R2 Connection Diagrams for Large Facility Central Monitor TL 2015R2...

Страница 3: ...SETTING UP AND INSTALLING THE CARE STATION 3 0 OPTIONAL INTERFACE EXPANSION UNIT 4 0 APPROVALS 5 0 SUMMARY OF FEATURES AND FUNCTIONS 6 0 TECHNICAL SPECIFICATIONS 7 0 USER INSTRUCTIONS 8 0 LIST OF COMP...

Страница 4: ...om ield equipment by providing different sound and display indications In addition a stand alone wireless transponder repeater unit WBUM 02 is available that can substantially increase the distance at...

Страница 5: ...ot work properly The hand held tester unit may help locate the source in this case c Testing the wireless transmission on the site Up to 80 metre 250ft wireless range between devices is normal for Sma...

Страница 6: ...op bit and no parity bit And the output looks like this Toilet Alert ID 010123 2011 01 26 16 27 06 2 1 6 Data In Out This is a spare port for future development 2 1 7 Relay O P May be used for Normall...

Страница 7: ...res The length of such cable extension can be up to 250 metres Each ield receiver can detect data signals from an area having a radius up to 50 metres 150ft subject to survey and system range testing...

Страница 8: ...terface interconnection cables If the interface unit CMJ 01 is to be employed and only it s incorporated ield data receiver is to be utilised a standard pre prepared cable connects between the Interfa...

Страница 9: ...ifferent or its transmission may be interference by other transmitters This is also applied to the extension s receivers through CMJ 01 Please refer to the bottom of TL 2015R2 for the frequency conigu...

Страница 10: ...ximum rating for relay output contacts 1 amp e g for door lock 6 Display Simultaneous alphanumeric text for several detected patient transmitter units These alerts rotate in the display window 7 User...

Страница 11: ...central monitor OORC system auto checking function if enabled Used to detect if a ield unit becomes faulty or wireless interference is sensed This is reported and indicated at the TL 2015R2 7 3 1 Wire...

Страница 12: ...cordless PAD you must irst is to register its ID in to TL 2015R2 So it needs the following functions to operate the registration Enter into setup mode You must use the caregiver key for this Press the...

Страница 13: ...S N number ID of TM 04 and 00 is the irst number room assigned for this ID Use A Key to increate the room number its range is from 00 to 25 Once conirm the number use C Key to enter to next display Sa...

Страница 14: ...its range is from 0 to 9 XXXX serial number ID of the recorded TM 04 Use A Key to show next record When it show QUIT applying Caregiver key can then quit the list function Or when it is showing a emp...

Страница 15: ...n added to the working list memory The TL 2015R2 is now checking this pad continuously looking for the handshake signal every 30 seconds If it does not see this signal for 10 minutes it will show the...

Страница 16: ...l Time Clock setup Real time clock setup function is under the SETUP menu use section 7 4 to go into setup mode And then select Clock Time 7 5 1 Change Date Use Caregiver key entering into the clock s...

Страница 17: ...using for TL 2015R2 it shows 203 only that TL 2015R2 interprets the room number as 20 and the bed number is 3 So in order to make it display correctly in TL 2015R2 for BTX 02 programming that at the R...

Страница 18: ...let button 007 Toilet button at position 007 LCD Display Toilet Alarm Area No 007 4 Wristband transmitter s Calls can be reset at the central monitor Note Due to the mobility of these units there is n...

Страница 19: ...number LCD Display Door Fault 02 Other faults that are indicated a Power loss on units with batteries Bed mon AC loss 203 power is lost on this unit Only sent once since can be used battery only LCD...

Страница 20: ...3004SYS TL 3005SYS Door monitor with LCD display and external strip receiver b TL 3004SYS TL 3005SYS Easy installed door strip monitor with no display display available on Central Monitor c TL 2012SR...

Страница 21: ...21 Inter connections to TL 2015R2 TL 2015R2 TL 2015R2...

Страница 22: ...22 TL 2015R2 TL 2015R2 Back View...

Страница 23: ...23 TL 2015R2 TL 2015R2 Interface Unit...

Страница 24: ...24 TL 2015R2 TL 3005 TL 2012SREV...

Страница 25: ...25 TL 2015R2 TL 2015R2 Back View TL 3005 TL 2012SREV TL 3005...

Страница 26: ...26 TL 2015R2 TL 3005 TL 2012SREV...

Страница 27: ...27 TL 2015R2 1 TL 2015R2 2 TL 2015R2 3 Multi TL 2015R2 Application...

Страница 28: ...28 TL 2015R2 TL 2015R2...

Страница 29: ...29 TL 2015R2 3 Multi TL 2015R2 Application TL 2015R2 1 TL 2015R2 2...

Отзывы: