background image

15

Eg. 

Then, use 

Caregiver key

 to cancel the “Delete” operation, or use A-Key to conirm the “Delete” operation. After 

conirmed the “Delete”, it shows “Erasing…” and then back to the record showing. 

Delete all records:

To delete all records, move it to “Erase All” under the “Cordless PAD” menu. Use Caregiver Key to conirm the 
erase operation. It shows “Erasing…” also and then quit to show “Add Rec. “.

  

-  Quit Cordless PAD setup mode

 

Move it to show “<Quit>”, use 

Caregiver key

 to quit this function, and go up to main menu selection.

7.4.2 Normal User Operation

The irst time a new pad is used (after being programmed in as above) the TL-2015R2 will show that this pad has 
been added to the working list memory. The TL-2015R2 is now checking this pad continuously looking for the 
handshake signal every 30 seconds. If it does not see this signal for 10 minutes it will show the pad lost signal 
and the user should check this pad.

-  Make “Add”

 

Pressing on the PAD, the TM-04 will then output “PAD-ON” message. The TL-2015R2  then shows  

 

 

“Added” message and add it into the PAD’s working list.

  

-  Make “Alarm”

 

After added into the TL-2015R2 working list, TL-2015R2 will monitor its state. When the PAD released,    

 

TL-2015R2 will output alert.

  

-  Make “Return”

 

Re-press the PAD again, TL-2015R2 gets the “Return” message and shows it out on the display.

  -  Make “Lost”

 

When TL-2015R2 cannot receive the RF message from the speciic TM-04, for about 10 minutes, it  

 

 

then shows “Lost” message. 

 

Reset PAD-Lost

## Room Bed S/N

* 01 ?1 ? ????

## Room Bed S/N

* 01 01 1 1234

Delete ?

“C-Key”

Содержание TL-2015R2

Страница 1: ...nd Nurse Call Paging System InstallationandUseInstructions 433 PGD Caegiver Pocket Pager with LCD Display 433 NC Wireless Nurse Call Button Optional Accessories SMART CAREGIVER C O RPO RAT I O N Tel 8...

Страница 2: ...2 Large Facility Central Monitor TL 2015R2 Connection Diagrams for Large Facility Central Monitor TL 2015R2...

Страница 3: ...SETTING UP AND INSTALLING THE CARE STATION 3 0 OPTIONAL INTERFACE EXPANSION UNIT 4 0 APPROVALS 5 0 SUMMARY OF FEATURES AND FUNCTIONS 6 0 TECHNICAL SPECIFICATIONS 7 0 USER INSTRUCTIONS 8 0 LIST OF COMP...

Страница 4: ...om ield equipment by providing different sound and display indications In addition a stand alone wireless transponder repeater unit WBUM 02 is available that can substantially increase the distance at...

Страница 5: ...ot work properly The hand held tester unit may help locate the source in this case c Testing the wireless transmission on the site Up to 80 metre 250ft wireless range between devices is normal for Sma...

Страница 6: ...op bit and no parity bit And the output looks like this Toilet Alert ID 010123 2011 01 26 16 27 06 2 1 6 Data In Out This is a spare port for future development 2 1 7 Relay O P May be used for Normall...

Страница 7: ...res The length of such cable extension can be up to 250 metres Each ield receiver can detect data signals from an area having a radius up to 50 metres 150ft subject to survey and system range testing...

Страница 8: ...terface interconnection cables If the interface unit CMJ 01 is to be employed and only it s incorporated ield data receiver is to be utilised a standard pre prepared cable connects between the Interfa...

Страница 9: ...ifferent or its transmission may be interference by other transmitters This is also applied to the extension s receivers through CMJ 01 Please refer to the bottom of TL 2015R2 for the frequency conigu...

Страница 10: ...ximum rating for relay output contacts 1 amp e g for door lock 6 Display Simultaneous alphanumeric text for several detected patient transmitter units These alerts rotate in the display window 7 User...

Страница 11: ...central monitor OORC system auto checking function if enabled Used to detect if a ield unit becomes faulty or wireless interference is sensed This is reported and indicated at the TL 2015R2 7 3 1 Wire...

Страница 12: ...cordless PAD you must irst is to register its ID in to TL 2015R2 So it needs the following functions to operate the registration Enter into setup mode You must use the caregiver key for this Press the...

Страница 13: ...S N number ID of TM 04 and 00 is the irst number room assigned for this ID Use A Key to increate the room number its range is from 00 to 25 Once conirm the number use C Key to enter to next display Sa...

Страница 14: ...its range is from 0 to 9 XXXX serial number ID of the recorded TM 04 Use A Key to show next record When it show QUIT applying Caregiver key can then quit the list function Or when it is showing a emp...

Страница 15: ...n added to the working list memory The TL 2015R2 is now checking this pad continuously looking for the handshake signal every 30 seconds If it does not see this signal for 10 minutes it will show the...

Страница 16: ...l Time Clock setup Real time clock setup function is under the SETUP menu use section 7 4 to go into setup mode And then select Clock Time 7 5 1 Change Date Use Caregiver key entering into the clock s...

Страница 17: ...using for TL 2015R2 it shows 203 only that TL 2015R2 interprets the room number as 20 and the bed number is 3 So in order to make it display correctly in TL 2015R2 for BTX 02 programming that at the R...

Страница 18: ...let button 007 Toilet button at position 007 LCD Display Toilet Alarm Area No 007 4 Wristband transmitter s Calls can be reset at the central monitor Note Due to the mobility of these units there is n...

Страница 19: ...number LCD Display Door Fault 02 Other faults that are indicated a Power loss on units with batteries Bed mon AC loss 203 power is lost on this unit Only sent once since can be used battery only LCD...

Страница 20: ...3004SYS TL 3005SYS Door monitor with LCD display and external strip receiver b TL 3004SYS TL 3005SYS Easy installed door strip monitor with no display display available on Central Monitor c TL 2012SR...

Страница 21: ...21 Inter connections to TL 2015R2 TL 2015R2 TL 2015R2...

Страница 22: ...22 TL 2015R2 TL 2015R2 Back View...

Страница 23: ...23 TL 2015R2 TL 2015R2 Interface Unit...

Страница 24: ...24 TL 2015R2 TL 3005 TL 2012SREV...

Страница 25: ...25 TL 2015R2 TL 2015R2 Back View TL 3005 TL 2012SREV TL 3005...

Страница 26: ...26 TL 2015R2 TL 3005 TL 2012SREV...

Страница 27: ...27 TL 2015R2 1 TL 2015R2 2 TL 2015R2 3 Multi TL 2015R2 Application...

Страница 28: ...28 TL 2015R2 TL 2015R2...

Страница 29: ...29 TL 2015R2 3 Multi TL 2015R2 Application TL 2015R2 1 TL 2015R2 2...

Отзывы: