background image

REV. 1-8-19  Page 36

Square Flat Disc Fire Pits

ON

OFF

AT ON POSITION  SLIGHT 

PUSH T

TURN OFF

FULL 

PUSH T

LIGHT

ON

OFF

AT ON POSITION 

SLIGHT 

PUSH T

TURN OFF

FULL 

PUSH T

LIGHT

ON

OFF

AT ON POSITION 

SLIGHT PUSH T

TURN OFF

FULL PUSH T

LIGHT

ON

OFF

AT ON POSITION 

SLIGHT PUSH TO 

TURN OFF

FULL PUSH TO 

LIGHT

ON

OFF

AT ON POSITION 

SLIGHT PUSH TO 

TURN OFF

FULL PUSH TO 

LIGHT

Position #2

Position #1

Position #3

The TMS valve bracket can be oriented in different positions to accommodate different installations.  Once the bracket 

and knob are installed, the knob may not be oriented in a convenient position to easily read.  If this is the case, we have 

provided a label that can be placed over top of the existing knob for the user to easily know which way to turn the control 

knob to light a fire pit.

The drawing below shows different positions bracket may be installed and which way to apply new label to better serve 
the user

.

f i r e - p a r t s . c o m

Содержание Firegear Outdoors FPB-25SFBSMT-N

Страница 1: ...t Disc TFS system FPB 25SFBSTFS P FPB 30SFBSMT N 30 Square Flat Disc MT system FPB 30SFBSMT P FPB 30SFBSTMSI N 30 Square Flat Disc TMSI system FPB 30SFBSTMSI P FPB 30SFBSTFS N 30 Square Flat Disc TFS...

Страница 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Страница 3: ...rial due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of...

Страница 4: ...B 30SFBSTMSI N FPB 30SFBSTMSI P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 30SFBSTFS N FPB 30SFBSTFS P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 34SFBSMT N FPB 34SFBSMT P 1 16 34 x 34 29 1 2 18 19 69 18 FPB 34SFBS...

Страница 5: ...5 0 WC 10 5 WC Table 3 Gas Pressures Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP at the burner orifice Flex line size and proper gas pipe sizing will...

Страница 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Страница 7: ...n of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must...

Страница 8: ...ION A minimum of 18 square inches of cross ventilation per side is required to keep the inside of the enclosure dry We recommend installation of a VENT KIT 6x12 See accessory section 8 These products...

Страница 9: ...ns Fig s 4 5 and 6 show the use of the flex frame system which provides the ability to easily remove the disc if necessary O N O F F O N O F F Fig 4 Show disc secured under stone caps Fig 5 Show disc...

Страница 10: ...se manner Secure into position See Fig 8 Fig 8 Installing OAS assembly to spur burner INSTALLING KEY VALVE The key valve contents 1 key valve 1 key and 1 flange See Fig 9 The valve requires a 1 round...

Страница 11: ...ve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Key Valve Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner Key PU...

Страница 12: ...6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause s...

Страница 13: ...sually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance MT TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 2 Ensure all gas...

Страница 14: ...y Valve Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threa...

Страница 15: ...Fig 16 Installing OAS assembly to spur burner Section B Thermocouple Manual Safety TMSI Installation Fig 14 Shows disc secured under stone caps Fig 15 Shows disc secured between layer of block NOTE A...

Страница 16: ...e gas valve is secured into the mounting plate with a nut Fig 17 shows an example of a typical installation Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner OFF Gas Valve TC Wire Pie...

Страница 17: ...ter than 1 inch overtop of the burner portholes Do NOT cover the screen mesh with any rock or glass It must be free an any debris to operate properly It is important check that the ignitor probes be p...

Страница 18: ...disconnected from its fuel supply Natural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance Fig 21 C...

Страница 19: ...ally a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TMSI TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 3 Ensure all gas...

Страница 20: ...s on all male NPT threads not flared fitting side Ensure all connections are tight and check for gas leaks before and after assembly is complete REV 1 4 19 Flare to 3 8 Male Thread Fitting Not Supplie...

Страница 21: ...ustrations below show examples of possible installations NOTE Additional methods of supporting the center of the disc underneath or supporting an oversized opening are shown on page 9 in Figs 6 7 Requ...

Страница 22: ...smitter and you will see a red LED light at the top of the transmitter glow The red LED light will only be lit when a button is pushed See Fig 27 Fig 26 Weatherproof cover lid installation INSTALLING...

Страница 23: ...A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes press and...

Страница 24: ...f Cover ON O F F Gas valve and flexible gas lines are supplied gas shut off is not supplied but available in accessories page Flex lines with flared fittings do not require Teflon tape or pipe compoun...

Страница 25: ...operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines...

Страница 26: ...w for proper flame sensing 5 Ensure orange white leads from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection o...

Страница 27: ...bstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system...

Страница 28: ...ouple over rainshield on page 24 Fig 31 2 Thermocouple reading should be between 10 20mV Test at the brass ground lead on gas valve and the gold lead at S terminal on the control module If no minimum...

Страница 29: ...ack Wire Flat Disc Pan Spur Burner Ignition Hood 7 8 Washer Brass Nut OAS NG Burner Orifice Coupler T 200 9898 46 Flex Conector Note Use joint compound or Teflon tape resistant to all gasses on all ma...

Страница 30: ...OT 10 11 12 13 Remote Off S I ADJ IPI POWER Learn AUX 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 22 23 24 28 29 18 30 36 37 38 21 Requires...

Страница 31: ...rome Plated Key 1 KEY PC 12 x 13 Chrome Cover Plate 1 CVR BVL2CP x 14 Thermocouple for TFS Pilot Must be ordered with item 15 1 ST3 040 1023 x 14 Thermocouple for TMSI Pilot 1 ST3 040 1025 x 15 Thermo...

Страница 32: ...eld Replacement Kit not shown 1 TFS IGNT ASSEMBLY x 40 Thermocouple Rainshield Replacement Kit not shown 1 TMS TC ASSEMBLY x 41 Manual Spark Ignitor Module not shown 1 3042 RB x 42 23 Piezo Extension...

Страница 33: ...x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Adapter Model ADP10 OUT 10 wire ADP70 OUT 70 wire Outdoor approved 7 5VDC adapter transformer elimi...

Страница 34: ...cation or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemical...

Страница 35: ...n to be easily read Note Mounting plate can also be installed into a paver control panel PAVER CP TMSI bracket system Using scissors carefully cutout the template and trace it on your concrete board T...

Страница 36: ...IGHT Position 2 Position 1 Position 3 The TMS valve bracket can be oriented in different positions to accommodate different installations Once the bracket and knob are installed the knob may not be or...

Страница 37: ...REV 1 8 19 Page 37 Square Flat Disc Fire Pits NOTES fire parts com...

Страница 38: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...

Отзывы: