Skytech Firegear Outdoors FPB-25SFBSMT-N Скачать руководство пользователя страница 34

REV. 1-8-19  Page 34

Square Flat Disc Fire Pits

Skytech Products Group (Firegear Outdoors) hereby warrants 

to the end user that products will be free from material and 

workmanship defects that prevent safe and correct operation of 

the product. The warranty commences from date of sale to the 

end user for the following period:

End User must provide a bill of sale, canceled check, or payment 

record from the end user to verify purchase date and to establish 

warranty period. This Limited Warranty shall be valid and limited 

to the original purchaser only.

WARNING Any modification to the product will void the warranty.

This Limited Warranty shall be limited to the repair and/or 

replacement of parts that have proven to be defective under 

normal use and service. Before returning any parts, contact 

our Technical Service Department for a Return Materials 

Authorization (RMA) number. All warranty claims must be made 

by the OEM / Distributor / Dealer account on behalf of the end 

user. You may contact Technical Service at (855) 498-8324.
All approved returned defects must be confirmed by our 

Technical Service Department. If the defect is confirmed and we 

approve the claim, we will replace such parts without charge. 

This warranty gives you specific legal rights, and you may also 

have other rights, which vary from state to state.

Travel, diagnostic cost, service labor to repair the defect and 

freight charges on warranty parts to and from the factory will 

be responsibility of the owner. We will not be responsible for 

labor charges and/or damage incurred in installation, repair, and 

replacement.

LIMITED WARRANTY

This Limited Warranty is voided if not assembled, installed 

and operated as intended. This Limited Warranty does not 

cover any defects due to accident, abuse, misuse, alteration, 

misapplication, vandalism, improper installation or improper 

maintenance or service, removal from the original location or 

re- installation into another location, or failure to perform normal 

and routine maintenance.

Damage due to severe weather conditions such as hail, 

hurricanes, earthquakes, tornadoes, discoloration due to over-

heating, exposure to chemicals (including salt), either directly or 

in the atmosphere, or very high humidity, is not covered by this 

Limited Warranty.

There are no other express warranties except as set forth herein. 

For consumer applications, any applicable implied warranties of 

merchantability and fitness are limited induration to the period 

of coverage of this Limited Warranty. Some states do not allow 

limitation on how long an implied warranty lasts, so this limitation 

may not apply to you.

For Commercial applications, the liability of Firegear Outdoors 

is limited to the express terms of this warranty. We expressly 

disclaim any and all implied warranties, including any warranties 

of fitness for a particular purpose or merchantability.

We are not liable for any special, indirect or consequential 

damages. Our maximum liability is limited to the purchase 

price of the purchased products. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so 

this limitation or exclusions may not apply to you.

We do not authorize any person or company to assume for it any 

other obligation or liability in connection with the sale, installation, 

use, removal, return, or replacement of its equipment; and no 

such representations are binding.

Lava Rock and Lava Stones are not

 covered by warranty

CONSUMER/NON-COMMERCIAL APPLICATIONS:
Stainless Steel Components

5 Years

Gas Valve, Spark Igniter & Electronic Parts

2 Years

Log Sets

3 Years

Glass Windshields

5 Years

Glass Media

1 Year

Controls

5 Years

AnF Enclosures

5 Years

GFRC (Glass Fiber Reinforced Concrete)

1 Year

COMMERCIAL APPLICATIONS:
Stainless Steel Components

1 Year

Gas Valve, Spark Igniter & Electronic Parts

1 Year

Log Sets

1 Year

Glass Windshields

1 Year

Glass Media

1 Year

Controls

1 Year

AnF Enclosures

1 Year

GFRC (Glass Fiber Reinforced Concrete)

1 Year

Lava Rock and Lava Stones are not

 covered by warranty

A DIVISION OF SKYTECH PRODUCTS GROUP

REV. 6/18

f i r e - p a r t s . c o m

Содержание Firegear Outdoors FPB-25SFBSMT-N

Страница 1: ...t Disc TFS system FPB 25SFBSTFS P FPB 30SFBSMT N 30 Square Flat Disc MT system FPB 30SFBSMT P FPB 30SFBSTMSI N 30 Square Flat Disc TMSI system FPB 30SFBSTMSI P FPB 30SFBSTFS N 30 Square Flat Disc TFS...

Страница 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Страница 3: ...rial due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of...

Страница 4: ...B 30SFBSTMSI N FPB 30SFBSTMSI P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 30SFBSTFS N FPB 30SFBSTFS P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 34SFBSMT N FPB 34SFBSMT P 1 16 34 x 34 29 1 2 18 19 69 18 FPB 34SFBS...

Страница 5: ...5 0 WC 10 5 WC Table 3 Gas Pressures Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP at the burner orifice Flex line size and proper gas pipe sizing will...

Страница 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Страница 7: ...n of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must...

Страница 8: ...ION A minimum of 18 square inches of cross ventilation per side is required to keep the inside of the enclosure dry We recommend installation of a VENT KIT 6x12 See accessory section 8 These products...

Страница 9: ...ns Fig s 4 5 and 6 show the use of the flex frame system which provides the ability to easily remove the disc if necessary O N O F F O N O F F Fig 4 Show disc secured under stone caps Fig 5 Show disc...

Страница 10: ...se manner Secure into position See Fig 8 Fig 8 Installing OAS assembly to spur burner INSTALLING KEY VALVE The key valve contents 1 key valve 1 key and 1 flange See Fig 9 The valve requires a 1 round...

Страница 11: ...ve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Key Valve Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner Key PU...

Страница 12: ...6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause s...

Страница 13: ...sually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance MT TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 2 Ensure all gas...

Страница 14: ...y Valve Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threa...

Страница 15: ...Fig 16 Installing OAS assembly to spur burner Section B Thermocouple Manual Safety TMSI Installation Fig 14 Shows disc secured under stone caps Fig 15 Shows disc secured between layer of block NOTE A...

Страница 16: ...e gas valve is secured into the mounting plate with a nut Fig 17 shows an example of a typical installation Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner OFF Gas Valve TC Wire Pie...

Страница 17: ...ter than 1 inch overtop of the burner portholes Do NOT cover the screen mesh with any rock or glass It must be free an any debris to operate properly It is important check that the ignitor probes be p...

Страница 18: ...disconnected from its fuel supply Natural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance Fig 21 C...

Страница 19: ...ally a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TMSI TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 3 Ensure all gas...

Страница 20: ...s on all male NPT threads not flared fitting side Ensure all connections are tight and check for gas leaks before and after assembly is complete REV 1 4 19 Flare to 3 8 Male Thread Fitting Not Supplie...

Страница 21: ...ustrations below show examples of possible installations NOTE Additional methods of supporting the center of the disc underneath or supporting an oversized opening are shown on page 9 in Figs 6 7 Requ...

Страница 22: ...smitter and you will see a red LED light at the top of the transmitter glow The red LED light will only be lit when a button is pushed See Fig 27 Fig 26 Weatherproof cover lid installation INSTALLING...

Страница 23: ...A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes press and...

Страница 24: ...f Cover ON O F F Gas valve and flexible gas lines are supplied gas shut off is not supplied but available in accessories page Flex lines with flared fittings do not require Teflon tape or pipe compoun...

Страница 25: ...operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines...

Страница 26: ...w for proper flame sensing 5 Ensure orange white leads from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection o...

Страница 27: ...bstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system...

Страница 28: ...ouple over rainshield on page 24 Fig 31 2 Thermocouple reading should be between 10 20mV Test at the brass ground lead on gas valve and the gold lead at S terminal on the control module If no minimum...

Страница 29: ...ack Wire Flat Disc Pan Spur Burner Ignition Hood 7 8 Washer Brass Nut OAS NG Burner Orifice Coupler T 200 9898 46 Flex Conector Note Use joint compound or Teflon tape resistant to all gasses on all ma...

Страница 30: ...OT 10 11 12 13 Remote Off S I ADJ IPI POWER Learn AUX 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 22 23 24 28 29 18 30 36 37 38 21 Requires...

Страница 31: ...rome Plated Key 1 KEY PC 12 x 13 Chrome Cover Plate 1 CVR BVL2CP x 14 Thermocouple for TFS Pilot Must be ordered with item 15 1 ST3 040 1023 x 14 Thermocouple for TMSI Pilot 1 ST3 040 1025 x 15 Thermo...

Страница 32: ...eld Replacement Kit not shown 1 TFS IGNT ASSEMBLY x 40 Thermocouple Rainshield Replacement Kit not shown 1 TMS TC ASSEMBLY x 41 Manual Spark Ignitor Module not shown 1 3042 RB x 42 23 Piezo Extension...

Страница 33: ...x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Adapter Model ADP10 OUT 10 wire ADP70 OUT 70 wire Outdoor approved 7 5VDC adapter transformer elimi...

Страница 34: ...cation or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemical...

Страница 35: ...n to be easily read Note Mounting plate can also be installed into a paver control panel PAVER CP TMSI bracket system Using scissors carefully cutout the template and trace it on your concrete board T...

Страница 36: ...IGHT Position 2 Position 1 Position 3 The TMS valve bracket can be oriented in different positions to accommodate different installations Once the bracket and knob are installed the knob may not be or...

Страница 37: ...REV 1 8 19 Page 37 Square Flat Disc Fire Pits NOTES fire parts com...

Страница 38: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...

Отзывы: