background image

REV. 1-8-19  Page 12

Square Flat Disc Fire Pits

CAUTION

: Children and adults should be alerted to the hazards on high surface temperatures and should stay away to 

avoid burns or clothing ignition. Young children should be carefully supervised when they are in the area of the appliance.

WARNING:

 Do not use this appliance if any part has been under water. Immediately call a qualified service technician 

to inspect the appliance and to replace any part of control system and any gas control, which has been under water.

OPERATION 

SAFETY WARNINGS

 1.  Never leave the fire pit unattended during operation. 

 2.  Clothing or other flammable materials should not be placed on or near the appliance.   

 3.  Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the  

 

     appliance.

 4.  Installation and repair should be done by a qualified service person. The appliance should be inspected before  

 

     use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It  

 

     is imperative the control compartment, burners and circulating air passageways of the appliance be kept clean.

 5.  Inspect the fuel supply connection before each use of the appliance.

 6.  Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply      

 

      (Natural or L.P. gas line).

WARNING

1. This appliance is hot when operated and can cause severe burns if contacted.

2.  Do not burn any solid fuels in this appliance.

LIGHTING INSTRUCTIONS

Key

Fig. 12

 Inserting Key into Valve

ON

O

FF

Fig. 11

. Key Valve Face

Butane Ligh

ter

READ ALL WARNING AND SAFETY INFORMATION ABOVE BEFORE 

ATTEMPTING TO LIGHT FIRE PIT

CAUTION

:   Ensure you have leak tested the fire pit before operating.

TURNING ON FIRE PIT

1.  Insert key into shut-off valve and secure into square end (see Figs 11 & 12).

2.  Light a long match or butane lighter and hold it near the burner (see Fig. 13).

3.  Turn the key counter-clockwise in gas valve (until it stops) to allow gas to flow and

     simultaneously apply the long burning match or Butane lighter as close to the end 

     burner as possible to light the fire pit.

4. Gas should ignite within 10 seconds or less.  If fire pit does not light within 10 seconds

    turn key clockwise to turn 

OFF

 the gas supply.  Ensure there is not too much media on 

    top of the burner that might inhibit gas flow and try again in 5 minutes.

TURNING OFF FIRE PIT

1. Insert key into shut-off valve and secure into square end.

2. Turn key clockwise until it stops.

3.  After cooling off install cover.

SECTION 

A - MA

TCH LIGHT (MT) INST

ALLA

TION

Fig. 13

 Using Butane lighter to light fire pit.

f i r e - p a r t s . c o m

Содержание Firegear Outdoors FPB-25SFBSMT-N

Страница 1: ...t Disc TFS system FPB 25SFBSTFS P FPB 30SFBSMT N 30 Square Flat Disc MT system FPB 30SFBSMT P FPB 30SFBSTMSI N 30 Square Flat Disc TMSI system FPB 30SFBSTMSI P FPB 30SFBSTFS N 30 Square Flat Disc TFS...

Страница 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Страница 3: ...rial due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of...

Страница 4: ...B 30SFBSTMSI N FPB 30SFBSTMSI P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 30SFBSTFS N FPB 30SFBSTFS P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 34SFBSMT N FPB 34SFBSMT P 1 16 34 x 34 29 1 2 18 19 69 18 FPB 34SFBS...

Страница 5: ...5 0 WC 10 5 WC Table 3 Gas Pressures Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP at the burner orifice Flex line size and proper gas pipe sizing will...

Страница 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Страница 7: ...n of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must...

Страница 8: ...ION A minimum of 18 square inches of cross ventilation per side is required to keep the inside of the enclosure dry We recommend installation of a VENT KIT 6x12 See accessory section 8 These products...

Страница 9: ...ns Fig s 4 5 and 6 show the use of the flex frame system which provides the ability to easily remove the disc if necessary O N O F F O N O F F Fig 4 Show disc secured under stone caps Fig 5 Show disc...

Страница 10: ...se manner Secure into position See Fig 8 Fig 8 Installing OAS assembly to spur burner INSTALLING KEY VALVE The key valve contents 1 key valve 1 key and 1 flange See Fig 9 The valve requires a 1 round...

Страница 11: ...ve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Key Valve Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner Key PU...

Страница 12: ...6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause s...

Страница 13: ...sually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance MT TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 2 Ensure all gas...

Страница 14: ...y Valve Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threa...

Страница 15: ...Fig 16 Installing OAS assembly to spur burner Section B Thermocouple Manual Safety TMSI Installation Fig 14 Shows disc secured under stone caps Fig 15 Shows disc secured between layer of block NOTE A...

Страница 16: ...e gas valve is secured into the mounting plate with a nut Fig 17 shows an example of a typical installation Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner OFF Gas Valve TC Wire Pie...

Страница 17: ...ter than 1 inch overtop of the burner portholes Do NOT cover the screen mesh with any rock or glass It must be free an any debris to operate properly It is important check that the ignitor probes be p...

Страница 18: ...disconnected from its fuel supply Natural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance Fig 21 C...

Страница 19: ...ally a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TMSI TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 3 Ensure all gas...

Страница 20: ...s on all male NPT threads not flared fitting side Ensure all connections are tight and check for gas leaks before and after assembly is complete REV 1 4 19 Flare to 3 8 Male Thread Fitting Not Supplie...

Страница 21: ...ustrations below show examples of possible installations NOTE Additional methods of supporting the center of the disc underneath or supporting an oversized opening are shown on page 9 in Figs 6 7 Requ...

Страница 22: ...smitter and you will see a red LED light at the top of the transmitter glow The red LED light will only be lit when a button is pushed See Fig 27 Fig 26 Weatherproof cover lid installation INSTALLING...

Страница 23: ...A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes press and...

Страница 24: ...f Cover ON O F F Gas valve and flexible gas lines are supplied gas shut off is not supplied but available in accessories page Flex lines with flared fittings do not require Teflon tape or pipe compoun...

Страница 25: ...operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines...

Страница 26: ...w for proper flame sensing 5 Ensure orange white leads from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection o...

Страница 27: ...bstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system...

Страница 28: ...ouple over rainshield on page 24 Fig 31 2 Thermocouple reading should be between 10 20mV Test at the brass ground lead on gas valve and the gold lead at S terminal on the control module If no minimum...

Страница 29: ...ack Wire Flat Disc Pan Spur Burner Ignition Hood 7 8 Washer Brass Nut OAS NG Burner Orifice Coupler T 200 9898 46 Flex Conector Note Use joint compound or Teflon tape resistant to all gasses on all ma...

Страница 30: ...OT 10 11 12 13 Remote Off S I ADJ IPI POWER Learn AUX 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 22 23 24 28 29 18 30 36 37 38 21 Requires...

Страница 31: ...rome Plated Key 1 KEY PC 12 x 13 Chrome Cover Plate 1 CVR BVL2CP x 14 Thermocouple for TFS Pilot Must be ordered with item 15 1 ST3 040 1023 x 14 Thermocouple for TMSI Pilot 1 ST3 040 1025 x 15 Thermo...

Страница 32: ...eld Replacement Kit not shown 1 TFS IGNT ASSEMBLY x 40 Thermocouple Rainshield Replacement Kit not shown 1 TMS TC ASSEMBLY x 41 Manual Spark Ignitor Module not shown 1 3042 RB x 42 23 Piezo Extension...

Страница 33: ...x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Adapter Model ADP10 OUT 10 wire ADP70 OUT 70 wire Outdoor approved 7 5VDC adapter transformer elimi...

Страница 34: ...cation or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemical...

Страница 35: ...n to be easily read Note Mounting plate can also be installed into a paver control panel PAVER CP TMSI bracket system Using scissors carefully cutout the template and trace it on your concrete board T...

Страница 36: ...IGHT Position 2 Position 1 Position 3 The TMS valve bracket can be oriented in different positions to accommodate different installations Once the bracket and knob are installed the knob may not be or...

Страница 37: ...REV 1 8 19 Page 37 Square Flat Disc Fire Pits NOTES fire parts com...

Страница 38: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...

Отзывы: