background image

Note:Two dimming wire in the driver box

Black

White

Neutral

Green/Yellow Green

Ground

Line

Purple

Gray

Wire Connection

Installation Guide

210mm

正面

297mm

LED AREA LIGHT

Installation Guide

WARNING

— To prevent personal injury or product damage only licensed electricians should install.

— To avoid electric shock or component damage disconnect power before attempting installation or servicing.

— This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety standards.

— Disconnect product and allow cooling prior to servicing.

— Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.

— To prevent product malfunction and/or electrical shock this product must be properly grounded.

— This luminaire is designed to operate in ambient temperatures ranging from -40°C to 45°C and to be horizontally mounted with the LEDs facing down.

— This product must be installed in accordance with the applicable installation code by a Person familiar with the construction and operation of the product and 

     the hazards involved.

— MIN 75°C SUPPLY CONDUCTORS

— CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR

— CAUTION - RISK OF FIRE

— Slipfitter Mounted with PHOTOCELL function elevation angle should not exceed 15 degrees

PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION

Square/Round Pole

Slipfitter

Wall Mount

BLACK

BLACK

BLACK

INPUT

LAMPLOAD

RED

PHOTOCONTROL

MOTION SENSOR

WHITE

WHITE

WHITE

1. Connect the wires to L / N / GND
2. Remove the cover and adjust the bracket to the desired angle
3. Install the bracket on the pole and fix it with screws

(Figure 1)

 Twisted photocell (optional)

PM4*12(mm) 

Screws

Side plate

OPEN

Mounting bracket

 5/16’’*1.02(inch) UNC Screws

1/2’’*1.97(inch) 

UNC Screws

Round pole 

mounting plate

Motion Sensor (optional)

PM4*8(mm) 

Screws

(Figure 2)

Side plate

5/16’’*1.02(inch) UNC Screws

 Twisted photocell (optional)

M8*20(mm) Screws

PM4*12(mm) Screws

(Figure 3)

1. Remove the side plate from mounting bracket. Please skip to 

step 3 if mounted onto the square Pole.

2. Attach round pole mounting plate on mounting bracket. 
3. Route the cord into mounting bracket through the hole for wiring, 

slide the fixture onto the bracket and tighten 2 bottom screws. 

4. Slightly drag the wires to make sure the hole on bracket is 

sealed by silicon gasket. 

5. Make wiring connection as per wire diagram below, replace 

the side plate and fasten screws.

1. Remove the side plate by loosen the screws. 
2. Fix the back plate onto the arm bracket with screws provided. 
3. Use the metal template provided to locate footprint on the wall 

to drill the holes, then fix the bracket on the wall with screws. 

4. Route the power cord into wall mount bracket, slide the fixture 

onto the mounting bracket, then tighten bottom screws. 

5. Make wiring connection inside of bracket and replace the 

side plate with screws.

5/16’’*1.02(inch) UNC Screws

 Twisted photocell (optional)

PM4*8(mm) Screws

Motion Sensor (optional)

Back plate

Side plate

1/2’’1.46(inch) UNC Screws

PM4*12(mm) Screws

KM4*10(mm) Screws

OPEN