E_MH_Mounting_instructions_Skylux_Cintralux_Alu_25mm_fixed_parts_flat_curb
01/04/2020
14/20
7. Top arches
Place the
top arches LP502 on top of the PC panels; at the location of the bottom arches. Secure the top arches
LP502 by means of the
end cap 46573 and the bolts M8 x 60 mm 15441 to the brackets 46577.
Do this at both ends of top arch LP502.
Pull this top arch until the aluminium top arch fits snugly against the multi-walled polycarbonate panel.
Do not fasten too tightly!
Wait a moment with placing the side top arches LP512, which will come at the ends of the barrel vaults.
8. End piece retainer sheet
Place the multi-walled
PC end piece retainer sheet 25 mm in the bottom profile end piece LP725 and make sure
that the
UV side of the panel is facing the outside of the barrel vault. The end piece retainer sheet must be the
same length as the bottom profile end piece.
LP502
Bracket
Bolt
M8 x 60
46573
End cap
PC 25 mm end piece retainer
sheet with UV side facing
outwards
LP725
Bottom profile
end piece
LP502
Top arch
46573
End cap
46577
Bracket
Bolt
M8 x 60
Filler panel (< 1050 mm)
Full panel width (1050 mm)