01/04/2020
13/20
E_MH_Mounting_instructions_Skylux_Cintralux_Alu_25mm_fixed_parts_flat_curb
Take hold of this
panel with the finishing profile LP025 and CLIP the feet over the lateral profile LP125, between
the bottom arches LP525. Bend the panel over the bottom arches LP525 and also clip the other side of the panel
with the finishing profile LP025 to the other lateral profile LP125.
Clips
Full panel widths (1050 mm) are always used, with the exception of the outer edges of the barrel vault towards
the end pieces; where
filler panels (sawn panel widths < 1050 mm) are used.
PC 25 mm
UV side facing upwards!
LP025
Finishing profile
Filler panel
PC 25 mm
UV side facing upwards!
LP025
Finishing profile
LP125
Lateral profile for flat curb
CLIPS
PC 25 mm
LP025
Finishing profile
LP025
Finishing profile
LP125
Lateral profile
CLIPS