Page 36
INE S.p.A.
Via Facca, 10 - 35013 Cittadella - PADOVA - ITALIA Tel. 049/9481111 - Fax 049/9400249 - [email protected] - www.ine.it
•
Press selector switch ‘E6’ in sequence for lighting
the LED related to the parameter to be changed, and
rotate ‘E6’ itself for changing the value.
The voltage parameter ‘V’ can be setting only in no
synergic MIG/MAG (see operation SET ->
SYN
).
Via selector switch ‘E7’ it is possible to set the welding
current, the wire speed and the piece thickness. For
modifying these values:
•
Press selector switch ‘E7’ in sequence for lighting
the LED related to the parameter to be changed, and
rotate ‘E7’ itself for changing the value.
By keeping selector switch ‘E6’ pressed for more than
two seconds, you will go into the SET mode, where you
can set the following advanced parameters:
•
Softstart
SOF
:
when the torch trigger is pressed the
wire is fed slowly, reaching the set speed only when
the welding arc strikes. It is automatically adjusted
(
SYN
on the display) or adjustable from 1 to 100% of
the speed set for the wire.
•
Burnback
BUR
:
it adjusts power delay with the aim
of optimising the end of the welding process (that is,
the length of the wire with respect to the end of the
torch). It is automatically adjusted (
SYN
on the
display) or adjustable from 1 to 100%.
•
Pre-gas
PRE
:
pre-gas time (seconds)
•
Post-gas
POS
:
post-gas time (seconds
•
Synergy
SYN
:
to turn the synergy mode ON (1) or
OFF (0). In the manual mode it lets the user set all
the parameters exactly as they would be for
traditional MIG/MAG generators (adjustment of wire
tension, inductance and speed). This selection is not
available in MIG P or MIG DP because the
parameters need to be synergically controlled for a
correct pulsed arc welding.
Other parameters that can only be set in MIG DP
welding (double-pulsed MIG):
•
Freq DP
DPF
:
double-pulse frequency from a
minimum of 0.1 Hz to a maximum of 5 Hz; this setting
changes the high/low pulses per cycle in Hz. The
higher the frequency the finer the ripple shape, the
more penetration is gained along with a higher speed
of pulses and travel speed
•
Duty DP
DPD
:
this setting changes the % of the
time the high pulse is used, so resulting in a hotter
weld with a broader weld width
•
Offset DP
DPO
:
sets the difference between the
peak current on the high and low pulse. The higher
the number increases the spacing between each
ripple shape. This setting is used in conjunction with
the Freq DP to obtain TIG like weld deposits
To change these parameters proceed as follows (the
figures shown above are an example of the screen
pages for setting the parameters):
•
Turn selector ‘E6’ to select the parameter to change.
•
Turn selector ‘E7’ to change its value.
•
Turn selector ‘E6’ to select another parameter or
press ‘E6’ to exit the ‘SET’ mode.
Concluding notes
By means of the connector ‘C6’ on the front panel, the
machine may be controlled using optional remote
controls. The selection of the remote control is
automatic when the connector is inserted and remains
in this way until it is physically disconnected.
Storing programs and general settings
It is possible to store tailored welding recipes by using
the ‘E7’ selector switch. In total, 100 programmes can
be stored.
After set all the desired parameters, access the storage
menu by pressing the selector ‘E7’ for two seconds.
Save a program:
•
Rotate knob ‘E6’ and select
STO
(Store).
•
Rotate knob ‘E7’ for choosing the desired memory
location, shown on display ‘D4’.
•
If such chosen memory number is blinking, it means
it is free. On the contrary, if it is steady lit, it means
that it is already occupied: by confirming the
operation, the existing programme will be
overwritten.
•
Press ‘E7’ for two seconds to confirm or ‘E6’ to
cancel. The LED lights up blue ‘
3
’ for 2 seconds
indicates the save operation is complete.
H