176
SJ6826RT, SJ6832RT
213560ABA
Section 5 – Procedures
Load Sensing System
Platform Loaded?
This message is prompting for confirmation that the platform is loaded to rated load Press ENTER to confirm if the
platform is loaded.
Please Lift
This message is prompting for the platform to be raised. The UP switch should be closed.
Please Lower
This message is prompting for the platform to be lowered. The DOWN switch should be closed.
Lift Empty
This message is displayed while the platform is being raised to the next measurement height, when an EMPTY
platform is being calibrated.
Lift Loaded
This message is displayed while the platform is being raised to the next measurement height, when a LOADED
platform is being calibrated.
Lifting
This message is displayed while the platform is being raised, during HEIGHT-only calibration.
Measuring #
This message is displayed when the platform is stopped during calibration, when the GP102 takes a measurement.
There is a short delay while the machine is allowed to stabilize after movement is stopped.
Must Go Down!
This message occurs if the wrong switch is closed when the GP102 is waiting for the platform to be lowered.
Must Go Up!
This message occurs if the wrong switch is closed when the GP102 is waiting for the platform to be raised.
Please Wait
This message indicates that the GP102 is busy; the delay is short (no more than 5 seconds).
Lower Empty
This message is displayed while the platform is being lowered to the next measurement height, when an EMPTY
platform is being calibrated.
Lower Loaded
This message is displayed while the platform is being lowered to the next measurement height, when an EMPTY
platform is being calibrated.
Lowering
This message is displayed while the platform is being lowered, during HEIGHT-only calibration.