164
SJ6826RT, SJ6832RT
213560ABA
Section 5 – Procedures
Load Sensing System
5.5 Load Sensing System
NOTE
Load sensing system should be tested on the
first anniversary of the unit being in service.
Afterwards, it should only be tested if major
component is replaced .
WARNING
Remove all equipment, tools, or accessories,
before starting system checks.
5.5-1 Calibrate Load/Checking Load
Procedure
1.
Ensure batteries are fully charged.
2.
Ensure you are familiar with the emergency
lowering system and that it is fully functional.
3.
Ensure fuel tank has enough fuel to carry out test.
4.
Perform system functionality check as listed in the
Operation manual.
5.
Fully-lower platform.
6.
Plug calibrator (EasyCal) into appropriate port on
GP102 overload sensing controller.
7.
Retract all extension decks.
8.
Place rated load centered onto empty platform.
Be sure to account for the weight, options or
accessories on the platform or railings or remove
all items.
9.
The following steps may trigger an overload
event, preventing upward motion on some
machines. If this occurs, fully-lower the platform
and repeat up to 2 more times. If overload is still
triggered, stopping motion, recalibrate as per
Step 16. If the overload prevents lowering, use
the emergency lowering procedure, as outlined in
Operation manual, to lower machine.
10.
Use base controls for all following movements.
Holding enable (or key) switch in platform mode
while calibrator is in use will prevent it from
returning to its main menu.
11.
If at any time it is not possible to perform the
required operation, go to Step 16.
12.
Select the Diagnostics>System>Height menu.
13.
Elevate until height is between 45% and 55%. Be
sure to watch for overhead obstructions during
this operation. If you accidentally pass 55%, lower
to less than 40% and elevate into the required
range. Ensure last motion was Raise and was at
least 2s in duration.
14.
Select the Diagnostics>System>Load menu.
15.
Load reading should range from 95% to 110%. If
not, recalibrate as per Step 16.
16.
If necessary, recalibrate as per procedure
listed in Service manual with the following
exceptions:
1.
Leave rated load on platform.
2.
When the calibrator displays Calibrate Load:
Empty? No, press Enter.
3.
When the calibrator displays Calibrate Load:
Loaded? No, using the UP button select
Calibrate Load: Loaded? Yes, and press Enter.
17.
Repeat Steps 6–16 as necessary. If test cannot
be passed after 2 calibration attempts, contact
Skyjack Customer Service.
18.
Fully lower platform.
19.
Remove load.
20.
Unplug calibrator.